Eliminating Minor Faults Yourself - Siemens FI24 Series Instructions For Use Manual

Hide thumbs Also See for FI24 Series:
Table of Contents

Advertisement

Eliminating minor faults yourself

Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following information.
Customer service will charge you for advice – even if the appliance is still under guarantee!
Appliance
Fault
Appliance has no refrigeration
capacity.
The light does not work.
The display does not illuminate.
The refrigeration unit is
switching on more frequently
and for longer.
The light (LED) does not work. The LED lamp is defective.
Display indicates "E..".
Display indicates
"LOWPOWER".
Display indicates "HIGHVOLT". The mains voltage exceeds
Possible cause
Appliance has been switched off.
Power failure.
The fuse has been switched off.
The mains plug has not been inserted
properly.
Appliance opened frequently.
The ventilation openings have been
covered.
Large quantities of fresh food are
placed in the freezer.
Light switch is jammed.
Electronics have detected a fault.
The mains voltage falls below
the permitted limiting value.
the permitted limiting value.
Remedial action
Press the On/Off button.
Check whether the power is on.
Check the fuse.
Check whether the mains plug is secure.
Do not open the appliance unnecessarily.
Remove obstacles.
Activate super freezing.
Call customer service.
Check whether it can be moved.
Call customer service.
When the mains voltage reaches
the stipulated value again, the warning
message goes out. If the warning message
lasts for longer, inform the energy supply
company.
When the mains voltage reaches
the stipulated value again, the warning
message goes out. If the warning message
lasts for longer, inform the energy supply
company.
en