Technibel KPAFM75R5I Technical Data & Service Manual page 8

Split system air conditioner
Table of Contents

Advertisement

KPAFM165/185R5I
Controller PCB
Part No.
Controls
Fan & Fan Motor
Type
Q'ty ....... Dia. and lenght
Fan motor model...Q'ty
No. Of poles...rpm (230 V, High)
Running Amps
Power input
Coil resistance (Ambient temp. 25 °C )
Safety devices
Run capacitor
Flap motor
Model
Rating
Rpm
Nominal output
Coil resistance
Electronic expansion valve
Coil
Valve body
Heat Exch. Coil
Coil
Rows
Fin pitch
face area
Type
Operating temp. Open
Close
(25°C)
2.... Ø 130 L 180
mm
K48410-MO1598 ...1
A
W
GRY-WHT: 124 ÷ 144
WHT-PNK: 255 ÷ 294
WHT-VLT: 69,3 ÷ 79,8
VLT-ORG: 69,3 ÷ 79,8
ORG-YEL: 200 ÷ 233
Internal thermal protector
°C
Automatic reclosing
°C
µF
VAC
W
kΩ
Aluminium plate fin / Copper tube
mm
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
8
CR-CRP50A-B
Microprocessor
cross-flow
4... 1340
0,41
88
145 ± 5K
2
440
M2LB24ZA12
240 VAC
2,5
3
15,62 ± 15%
UKV-U030E
UKV-25D32
3
1,6
0,167

Advertisement

Table of Contents
loading

Table of Contents