1-2 Major Component Specifications

KPAFM75/95/125R5I
Controller PCB
Part No.
Controls
Fan & Fan Motor
Type
Q'ty ....... Dia. and lenght
Fan motor model...Q'ty
No. Of poles...rpm (230 V, High)
Running Amps
Power input
Coil resistance (Ambient temp. 25 °C )
Safety devices
Run capacitor
Flap motor
Model
Rating
Rpm
Nominal output
Coil resistance
Electronic expansion valve
Coil
Valve body
Heat Exch. Coil
Coil
Rows
Fin pitch
face area
Type
Operating temp. Open
Close
(25°C)
2.... Ø 130 L 180
mm
K48407-MO1596 ...1
A
W
GRY-WHT: 194 ÷ 223
WHT-PNK: 238 ÷ 274
WHT-VLT: 80,1 ÷ 92,2
VLT-ORG: 80,1 ÷ 92,2
ORG-YEL: 200 ÷ 230
Internal thermal protector
°C
Automatic reclosing
°C
µF
VAC
W
kΩ
Aluminium plate fin / Copper tube
mm
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
7
CR-CRP50A-B
Microprocessor
cross-flow
4... 1160
0,29
65
145 ± 5K
1,5
450
M2LB24ZA12
240 VAC
2,5
3
15,62 ± 15%
UKV-U030E
UKV-18D31
2
1,8
0,167