Communication Parameters - LG 47LD950 Owner's Manual

47" lcd 3d tv ready with 200hz, 4 x hdmi and usb connectivity
Table of Contents

Advertisement

APPENDIX

Communication Parameters

Baud rate : 9600 bps ( UART )
A
Data length : 8 bits
A
Parity : None
A
Command Reference List
01. Power
02. Aspect Ratio
03. Screen Mute
04. Volume Mute
05. Volume Control
06. Contrast
07 . Brightness
08. Colour
09. Tint
10. Sharpness
1 1. OSD Select
1 2. Remote control lock mode k
1 3. Treble
1 4. Bass
1 5. Balance
1 6. Colour Temperature
1 7 . Energy Saving
1 8. Auto Configuration
19. Tune Command
20. Programme Add/Skip m
21. Key
22. Control Back Light
23. Input select (Main)
* When setting the 17 to 23, a menu does not appear on screen.
* Note : During USB operations such as DviX or EMF, all commands
except Power(ka) and Key(mc) are not executed and treated as
NG.
106
Stop bit : 1 bit
A
Communication code : ASCII code
A
Use a crossed (reverse) cable.
A
COMMAND
COMMAND
DATA
1
2
(Hexadecimal)
k
a
00 to 01
k
c
Refer to
k
d
00 to 01
k
e
00 to 01
k
f
00 to 64
k
g
00 to 64
k
h
00 to 64
k
i
00 to 64
k
j
00 to 64
k
k
00 to 64
k
l
00 to 01
m
00 to 01
k
r
00 to 64
k
s
00 to 64
k
t
00 to 64
k
u
00 to 02
j
q
00 to 04
j
u
01
m
a
Refer to
b
00 to 01
m
c
Key C ode
m
g
00 to 64
x
b
Refer
to p. 1 10
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1] : First command to control the TV.
* [Command 2] : Second command to control the TV.
* [Set ID]
: You can adjust the set ID to choose
p. 107
* [DATA]
: To transmit command data.
* [Cr]
: Carriage Return
* [ ]
: ASCII code 'space (0x20)'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the
p. 109
data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving abnormal data from
non-viable functions or communication errors.
Data 00: Illegal Code
(j, k, m or x)
desired monitor ID number in option
menu. Adjustment range is 1 to 99.
When selecting Set ID '0' , every connected
set is controlled.
Set ID is indicated as decimal (1 to 99)
on menu and as Hexa decimal (0x0 to
0x63) on transmission/receiving protocol.
Transmit 'FF' data to read status of command.
ASCII code '0x0D'