11.4.4. Connect The Cable To The Outdoor Unit
a) Indoor Power Supply Model (3/4 ~ 2.5HP)
1. Remove the control board cover from the unit by
loosening the screw.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 5 u 1.5 mm
(3/4 ~ 1.5HP), 5 u 2.5 mm
type designation 245 IEC 57 or heavier cord.
3. Secure the cable onto the control board with the holder
(clamper).
4. Attach the control board cover back to the original
position with the screw.
5. For wire stripping and connection requirement, refer to
instruction 5 of indoor unit.
b) Outdoor Power Supply Model (3.0HP)
1. Remove the control board cover from the unit by
loosening the screw.
2. Connect approved type polychloroprene sheathed power
supply cord 3 x 4.0 mm
IEC 57 or heavier cord to the terminal board, and connect
the other end of the cord to Isolating Devices
(Disconnecting means).
3. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed 6 × 1.5 mm
flexible cord, type designation 245 IEC 57 or heavier
cord.
4. Connect the power supply cord and connecting cable
between indoor unit and outdoor unit according to the dia-
gram below.
5. Secure the power supply cord and connecting cable onto
the control board with the holder.
6. Attach the control board cover back to the original
position with screw.
7. For wire stripping and connection requirement, refer to
instruction 5 of indoor unit.
11.4.5. Pipe Insulation
1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap
the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E
FOAM with thickness 6mm or above.
2
(2.0 ~ 2.5HP) flexible cord,
2
(3.0HP), type designation 245
2
2
25