PROGRAMMING MODE - TEST MODE
PROGRAMMING MODE -
Diagnostic tests:
This program has been added for testing the washer and detecting errors.
Entering the test mode
Data Name
Entering
1. Entering programming mode
the test mode
2. WHITES
3. START
1.
According to pressing START button, test move to the next step.
Number of times the
START button is pressed
None
1time
Turns on all lamps and locks the door
2 times
Tumble Clockwise.
3 times
Low Speed Spin
4 times
High Speed Spin
5 times
Inlet valve for main water turns on.
6 times
Inlet valve for hot wash turns on.
7 times
Inlet valve for softener turns on.
8 times
Inlet valve for bleach turns on.
9 times
Tumble counter clockwise.
10 times
Drain Pump turns on.
11 times ( * )
Turn on Circulation Pump.
12 times
Turns on all lamps.
13 times
Button Checks.
14 times
High Speed Spin
15 times
16 times
NOTE
• Make sure the drum is empty when a diagnostic test is performed. Do not use
• * This machine do not use circulation system.
TEST MODE
(display)
Button
Display
Check Point
PDA Signal Check
Description
Insert service card (card type), turn on/off toggle switch (Coin type).
Press the WHITES button. Then
Enter the diagnostic test mode.
Displayed gX XX and AU XX alternately (Version)
rpm (40~50)
rpm (600)
rpm (1000~1150)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
rpm (40~50)
Water level frequency (261~)
Displayed 0XX
Displayed gX XX and AU XX alternately
Displayed gX XX and AU XX alternately
rpm(1150)
this function is not applied in this machine
appears in the display.