Preparation
Step 1.1 Choosing the installation
location
Overview of installation location requirements
125 mm
or more
Drain hose hole
You can select the direction of
draining (left or right).
Maximum pipe height: 8/15 m
Maximum pipe length: 15/30 m
Make at least one round to
reduce noise and vibration.
The actual units may look different from
Model
Minimum
007/009/012
018/024
Outdoor
Unit
Outer wall
Indoor
Unit
Cut insulation to have
rainwater drained
CAUTION
• Comply with the length and height limits described in
the figure above.
32 English
100 mm or more
125 mm
or more
the images depicted here.
(Unit : m)
Pipe length
Pipe height
Maximum
Maximum
3
15
8
3
30
15
Make a U-trap (A) on the
pipe (which is connected to
CAUTION
the indoor unit) at outer wall
and cut the bottom part of
the insulation (about 10 mm)
to prevent rainwater from
getting inside through the
insulation.
Step 1.2 Checking and preparing
accessories and tools
Accessories
Accessories in the indoor unit package
Installation plate (1)
Remote control battery (2)
NOTE
• A flare nut is attached to the end of each pipe of an
evaporator or a service port. Use flare nuts when
connecting the pipes.
Tools
General tools
• Vacuum pump
(Backward flowing
prevention)
• Manifold gauge
• Stud finder
• Torque wrench
• Pipe cutter
• Reamer
Tools for test operation
• Thermometer
• Resistance meter
• Electroscope
Remote control (1)
User & Installation Manual (1)
• Pipe bender
• Spirit level
• Screwdriver
• Spanner
• Drill
• L-wrench
• Measuring tape

Advertisement