Mitsubishi Electric PUHZ-W112VHA Service Manual page 39

Air to water heat pump
Hide thumbs Also See for PUHZ-W112VHA:
Table of Contents

Advertisement

SW2 setting
Outdoor unit setting information
ON
1
2 3 4 5 6
Plate HEX liquid pipe temperature (TH6)
−39 to 88
ON
1
2 3 4 5 6
Condensing temperature (T
−39 to 88
ON
1
2 3 4 5 6
Calculated maximum frequency
0 to 150
ON
1
2 3 4 5 6
Water inlet temperature (TH32)
ON
0 to 100
1
2 3 4 5 6
Ambient temperature (TH7)
−39 to 88
ON
1
2 3 4 5 6
Outdoor heat sink temperature (TH8)
−40 to 200
ON
1
2 3 4 5 6
Discharge superheat (SHd)
0 to 255
ON
Cooling and Heating: SHd = TH4 − T
1
2 3 4 5 6
OCH562D
Display detail
)
63HS
63HS
39
The black square (
Explanation for display
• The tens digit (Total display for applied setting)
Setting details
Display details
H·P / Cooling only
0: H·P
Single phase / 3 phase
0: Single phase 2: 3 phase
• The ones digit
Setting details
Display details
Defrosting switch
0: Normal
(Example) When heat pump, 3 phase and defrosting
(normal) are set up, "20" is displayed.
−39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
−39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
0 to 150
(When it is 100 Hz or more, hundreds digit, tens
digit and ones digit are displayed by turns.
(Example) When 105 Hz;
0.5 s
0 to 100
−39 to 88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
−40 to 200
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
(When the thermistor detects 100: or more,
hundreds digit, tens digit and ones digit are
displayed by turns.)
0 to 255
(When the SHd is 100°C or more, hundreds
digit, tens digit and ones digit are displayed by
turns.)
) indicates a switch position.
1: Cooling only
1: For high humidity
0.5 s
2 s
1
05
Unit
Code
display
:
:
Hz
:
:
:
°C