Advertisement

WWW.BROAN.COM
WWW.BROAN.CA
RANGE HOOD
Series: BKDB1, BKDEG1, BKSA1 and BKSH1
INSTALLATION, USE
AND CARE MANUAL
English - See page 2
HOTTE
DE CUISINIÈRE
Séries : BKDB1, BKDEG1, BKSA1 et BKSH1
MANUEL D'INSTALLATION,
D'UTILISATION ET D'ENTRETIEN
Français - Voir en page 31
CAMPANA
DE COCINA
Series: BKDB1, BKDEG1, BKSA1 y BKSH1
MANUAL DE INSTALACIÓN,
USO Y CUIDADO
Español - Vease la pagína 60
Serial number:
99045655-002D

Advertisement

Table of Contents
loading

Summary of Contents for Broan BKSA1

  • Page 1 Series: BKDB1, BKDEG1, BKSA1 and BKSH1 INSTALLATION, USE AND CARE MANUAL English - See page 2 HOTTE DE CUISINIÈRE Séries : BKDB1, BKDEG1, BKSA1 et BKSH1 MANUEL D’INSTALLATION, D’UTILISATION ET D’ENTRETIEN Français - Voir en page 31 CAMPANA DE COCINA Series: BKDB1, BKDEG1, BKSA1 y BKSH1 MANUAL DE INSTALACIÓN,...
  • Page 2: Table Of Contents

    Connect the Wiring ..... . 21 Light Bulbs (BKSA1 and BKSH1 Series only) . 22 Install the Filter(s) ..... . . 22 Wiring Diagrams .
  • Page 3: Safety

    READ AND SAVE THESE INSTRUCTIONS Intended for domestic cooking only INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. In U.S.A., register your range hood online at www.broan.com In Canada, register your range hood online at www.broan.ca WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: •...
  • Page 4 WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
  • Page 5: Operation

    Operation Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and fresher. Operate the hood as follows: BKDB1 BKDEG1 SERIES...
  • Page 6 BKSA1 SERIES BLOWER SWITCH LIGHT SWITCH Turns blower on to LOW speed. Turns light on in LOW intensity. • • Turns blower OFF. Turns light OFF. Turns blower on to HIGH speed. Turns light on to HIGH intensity. BKSH1 SERIES...
  • Page 7: Cleaning And Maintenance

    Cleaning and Maintenance Proper maintenance of the Range Hood will assure proper performance of the unit. MOTOR The motor is permanently lubricated and never needs oiling. If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The fan blade should also be replaced.
  • Page 8: Installation

    Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical access hole) • 7/64” drill bit (to drill holes for EZ1 brackets mounting screws, not for BKSA1 Series) • Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet) •...
  • Page 9: Contents

    Maximum Duct Lengths Recommended to Achieve 80% Exhaust Efficiency 7” R OUND OOF OR 3¼” 10” H 3¼” 10” V ORIZONTAL ERTICAL LBOW AXIMUM ALL CAP (90° 45°) AXIMUM UCT LENGTH AXIMUM UCT LENGTH UCT LENGTH WITH AMPER 68 ft. 51 ft.
  • Page 10 BKSH1 Series BKSA1 Series (2) S HIELDED ALOGEN ULBS (50W, GU10) (2) G (1) G REASE ILTERS REASE ILTER IND INSIDE OF HOOD IND INSIDE OF HOOD (2) S HIELDED ALOGEN ULBS (50W, GU10) (1) 7” R OUND (1) 3¼”...
  • Page 11: Prepare The Hood

    3 ] Remove the EZ1 brackets from inside the hood by cutting off the tie wrap (no EZ1 brackets in BKSA1 Series). Remove both screws holding damper assembly to hood. Remove parts bag (captured behind the damper assembly). Remove damper assembly from inside the hood and keep the screws for further use.
  • Page 12 5 ] Remove 7” Round Duct Plate from top/back of hood (see illustration below). 7” ROUND DUCT PLATE 2 SCREWS 6 ] Remove Electrical Power Cable Knockout from top (vertical exhaust) or back (horizontal exhaust) of hood. Install an appropriate strain relief, 1/2” diameter (not included). ELECTRICAL POWER CABLE KNOCKOUT...
  • Page 13 DUCTED INSTALLATION ONLY 8 ] Remove 3¼” x 10” vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate as appropriate for your ducting method (see F 1 A and 1 B). IGURES IGURE IGURE 7” ROUND KNOCKOUT PLATE ( ALSO REMOVE VERTICAL KNOCKOUT PLATE 3¼”...
  • Page 14: Prepare The Hood Location

    This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 one-person installation system (using included template and brackets). Please note that the EZ1 one-person installation system is not available for the BKSA1 Series. For the standard installation, go to page 19.
  • Page 15 4 ] Drill a 1/8” dia. pilot hole for house wiring, at A location on template. 5 ] Use a sharp pencil or 1/8” drill bit to mark the locations for the appropriate duct access holes (16 locations for 7” round duct, or 4 corner locations for rectangular duct). Remove the template.
  • Page 16 FRAMELESS CABINET Refer to the marking on brackets to determine the correct installation side and orientation. 7/64”  Align the corresponding bracket to the cabinet side, while placing rear end of bracket against the wall. Draw a line on the outer edge of the bracket (as shown). ...
  • Page 17: Install The Hood (Ez1 Bracket)

    Install the Hood (EZ1 Bracket) OTE: The following procedure applies to both framed or frameless cabinet installations. 1 ] Run house power cable between service panel and hood location. 2 ] There are 2 pairs of recessed holes on each side of the top of the hood (on rear: A and B, on front C and D on illustration below);...
  • Page 18 7 ] For framed cabinet, secure the hood to the EZ1 brackets using 4 no. 8-18 x 1/2” metal screws with washers (screws and washers included in parts bag). Insert 2 screws and washers per side, in the slots (as shown in inset on illustration below). 8 ] For frameless cabinet, secure the hood to the cabinet using 4 no.
  • Page 19: Standard Installation

    Standard Installation (without EZ1 brackets) 1 ] Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole, only cut the hole for electrical wiring. 3¼"...
  • Page 20: Install The Hood (Standard Installation)

    Install the Hood (Standard Installation) 1 ] Run house power cable between service panel and hood location. Run the house power cable into the hood through the strain relief previously installed in step 6 on page 12. 2 ] Hang hood from (4) mounting screws previously installed. Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood.
  • Page 21: Connect The Wiring

    Connect the Wiring WARNING Risk of electric shock. Electrical wiring must be done by qualifi ed personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.
  • Page 22: Light Bulbs (Bksa1 And Bksh1 Series Only)

    Light Bulbs (BKSA1 and BKSH1 Series only) The BKSA1 and BKSH1 Series range hoods require two shielded Halogen Bulbs (120 V, 50 W max., MR16 or PAR16 with GU10 base), included. WARNING Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury, only install shielded halogen lamps.
  • Page 23: Wiring Diagrams

    BKDB1 SERIES...
  • Page 24 BKDEG1 SERIES...
  • Page 25 BKSA1 BKSH1 SERIES...
  • Page 26: Service Parts

    ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing.
  • Page 27 ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing.
  • Page 28 ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing.
  • Page 29 ARTS AND EPAIRS In order to ensure your unit remains in good working condition, you must use Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts only. Broan-NuTone LLC or Broan-NuTone Canada ULC genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing.
  • Page 30: Warranty

    If you cannot provide a copy of the original written limited warranty, then the terms of the Company’s most current written limited warranty for your particular product will control. The most current limited written warranties for the Company’s products can be found at www.broan.com and www.broan.ca. Broan-NuTone LLC 926 West State Street, Hartford, WI 53027 www.broan.com...

Table of Contents