Automatic Defrost; Overload Protection - Prem-I-Air EH1910 Manual

12,000btu mobile portable local air conditioner with remote control, timer and wi-fi
Table of Contents

Advertisement

At low room temperatures, frost may build up at the evaporator during operation. The unit will automatically start
defrosting and the POWER LED will blink. The defrost control sequence is as follows: When the unit is operating in
cooling or drying mode, and the evaporator coil temperature is below -1°C, the compressor will stop operating for 10
minutes until the coil temperature is up to 7°C – the unit will then restart to cool operating mode.
In the event of a power loss, to protect the compressor, there is a 3-minute delay until the compressor restarts.
The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance.
There is no need to empty the drainage tank in cooling operation except in exceptionally high humidity conditions.
The condensate water evaporates at the condenser and is evacuated through the exhaust hose.
For continuous operation un drying mode, please connect the attached drain hose to the unit. Condensate water can
then be directly drained into a bucket or similar.
Switch off the unit before this operation
Remove the plug of the water outlet opening and keep
it in a safe place
Securely and properly connect the drain hose and
ensure it is not kinked and is clear of obstruction
Place the outlet of hose over a drain or a bucket and
ensure that water can flow freely out of the unit
Do not submerge the end of the hose into water, as this
can cause an "air lock" in the hose
To avoid water spillage, tilt the drain hose down
towards the floor and straighten out any kinks in the
hose
Note: Remember to replace the plug after using the
drain hose!

AUTOMATIC DEFROST

OVERLOAD PROTECTION

DRAINAGE