Broadcloud hosted uc solution using crp (50 pages)
Summary of Contents for AudioCodes Mediant 2600B
Page 1
Hardware Installation Manual AudioCodes One Voice™ for Microsoft Skype for Business Mediant 2600B Survivable Branch Appliance (SBA) for Skype for Business...
Replacing the SBA CPU Module ................50 Installing the MPM Modules .................. 52 Installing the OSN Server Modules ............... 54 Replacing the Fan Tray Modules ................56 Replacing the Power Supply Modules ..............58 Survivable Branch Appliance Mediant 2600B SBA...
Page 4
Mediant 2600B SBA List of Figures Figure 3-1: Front Panel .......................... 16 Figure 3-2: Module Slot Assignment on Front Panel ................17 Figure 3-3: SBA CPU Module ........................ 18 Figure 3-4: SBA CPU Module Ports ...................... 18 Figure 3-5: SBA CPU Module LEDs ...................... 19 Figure 3-6: MPM LEDs (e.g.
Page 6
Mediant 2600B SBA This page is intentionally left blank. Hardware Installation Manual Document #: LTRT-39392...
Page 7
Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner. For more information on how to buy technical support for AudioCodes products and for contact information, please visit our website at https://www.audiocodes.com/services-support/maintenance-and-support.
Page 8
Mediant 2600B SBA Notes and Warnings Warning: The device is an INDOOR unit and thus, must be installed ONLY indoors. In addition, Ethernet port interface cabling must be routed only indoors and must not exit the building. Avertissement: L’appareil est une unité d’INTERIEUR et doit donc obligatoirement être installé...
Page 10
Mediant 2600B SBA Documentation Feedback AudioCodes continually strives to produce high quality documentation. If you have any comments (suggestions or errors) regarding this document, please fill out the Documentation Feedback form website https://online.audiocodes.com/documentation-feedback. Hardware Installation Manual Document #: LTRT-39392...
This document provides a hardware description of the Mediant 2600B (hereafter referred to as device) and step-by-step procedures for cabling the device. Note: For configuring the device, refer to the Mediant 2600B SBA for Microsoft Skype for • Business Installation and Maintenance Manual.
Page 12
Mediant 2600B SBA This page is intentionally left blank. Hardware Installation Manual Document #: LTRT-39392...
Business Server) • Microsoft Windows 2008 R2 license Skype for Business Server license (envelope) • Check, retain and process any documents. If there are any damaged or missing items, notify your AudioCodes sales representative. Survivable Branch Appliance Mediant 2600B SBA...
Page 14
Mediant 2600B SBA This page is intentionally left blank. Hardware Installation Manual Document #: LTRT-39392...
Weight Approx. 7.4 kg (16.3 lbs.) with basic hardware configuration (i.e., without MPM and OSN server modules). For chassis weight of specific hardware configurations, please contact your AudioCodes sales representative. Operational: 0 to 40°C (32 to 104°F) Environmental Storage: -20 to 70°C (-4 to 158°F) ...
Figure 3-1: Front Panel Note: The figure above provides only an example of the Mediant 2600B. The modules housed in your Mediant 2600B may be slightly different, depending on the ordered hardware configuration. For module slot assignment, see Section 3.2.1...
26. 3.2.1 Module Slot Assignment The slot assignments on the front panel for the various modules per hardware configuration are shown in the figure below: Figure 3-2: Module Slot Assignment on Front Panel Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 3.2.2 SBA CPU Module The SBA CPU module provides the main functionalities of the device. These functionalities include the central processor unit (CPU), Ethernet port interfaces, serial interface, and a reset pinhole button. Figure 3-3: SBA CPU Module For replacing the SBA CPU module, see Section on page 50.
During booting up state. Booting up phase / fault detected in module. Green Normal operation. During booting up state. Green Application running in Standalone state. Flashing Application running in High Availability (HA) Active state. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Item # Color State Description Yellow Application is starting Boot / synchronizing Flashing Application is running in HA Redundant state. Out of service. Normal operation. Left Green Ethernet link established. Ethernet Flashing Data is being received or transmitted Port LED (activity) on the Ethernet port.
If this occurs, push on the handle until it is flush with the chassis (i.e. module locked in the slot). Module handle is locked (i.e., module is securely installed in the slot). Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 3.2.4 OSN Server Modules The OSN4 server modules are customer-ordered items. The OSN server consists of two modules: OSN4 - central processing unit (CPU), RAM, and port interfaces HDMX - hard-disk drive (HDD or SSD) providing storage capacity ...
LED locations): Upon reset: LED #1: On (solid green) LED #2: On (solid red) LED #5: On (solid blue) End of reset: LED #1 remains on (solid green); all other LEDs off. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 3.2.4.1.2 LED Description The LEDs of the OSN4 module are shown in the figure below and described in the subsequent table. Figure 3-8: OSN4 Module LEDs Table 3-8: OSN4 Module LED Description Item Color State Description Green...
No power received by module. Hard disk drive in use (active). Hard disk drive not in use. Blue Module can be extracted from chassis slot once dismounted from the OSN operating system. Module correctly inserted in chassis slot Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 3.2.5 Fan Tray Module The device provides two Fan Tray modules, located on either side of the chassis. Each module contains five integrated fans which cool the device's internal components. The Fan Tray module located on the left side of the chassis draws air from the outside through its' perforated grill.
Power status LED for indicating the status of the Power Supply module. For more information, see Section 3.3.1 on page 28. Extraction-handle for removing the Power Supply module. 100-240V~7A AC power supply inlet (100-240V~7A, 50-60 Hz) of 50-60Hz Power Supply module. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 3.3.1 Power Supply Modules The chassis houses two Power Supply modules for providing power load sharing and AC power redundancy in case of failure of one of the Power Supply modules. Each module is associated with an AC power inlet located on the rear panel of the chassis for connection to an electrical power outlet.
Peel off the adhesive, anti-slide rubber feet (supplied) and stick one in each anti-slide groove. Flip the device over again so that it rests on its underside with the rubber feet in contact with the surface. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 19-Inch Rack Mounting The device is designed to fit into a 19-inch industrial rack of 1 rack-unit height (1U). You can mount it in the rack using any one of the following mounting options: (Recommended) Mounting the chassis on a pre-installed shelf in a 19-inch rack – see ...
Secure the front-mounting brackets to the rack posts using standard 19-inch rack bolts (not supplied). This step is crucial in that it prevents the chassis from accidently sliding off the shelf. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA 4.2.2 Mounting in a 19-inch Rack using Front and Rear Brackets The device can be mounted in a 19-inch rack by attaching the chassis directly to the rack frame, using both front- and rear-mounting brackets. The device is shipped with two types...
See the figure below for correct orientation of the brackets when attaching them to the posts. Figure 4-3: Rear-Mounting Brackets Attached to Rear-Rack Posts (60 cm) Figure 4-4: Rear-Mounting Brackets Attached to Rear-Rack Posts (80 cm) Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Attach the rear-mounting flanges to the rear sides of the chassis, using three screws (supplied) per flange. Figure 4-5: Attaching Rear-Mounting Flange to Chassis' Rear-Side Mounting Holes (60 cm) Figure 4-6: Attaching Rear-Mounting Flange to Chassis' Rear-Side Mounting Holes (80 cm) With two people, lift the chassis into the rack from the front of the rack.
For 80-cm rear mounting, up to two screws can be used to secure the flange to the rear-mounting bracket (if required). Figure 4-9: Fastening Rear-Mounting Flange to Rear-Mounting Bracket (60 cm) Figure 4-10: Fastening Rear-Mounting Flange to Rear-Mounting Bracket (80 cm) Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Hold the chassis for support while the second person positions the chassis so that the front-mounting brackets are flush against the front-rack posts and the holes of the front-mounting brackets align with the holes on the front-rack posts.
This section describes how to cable the device: Connecting to the LAN – see Section on page Connecting to a computer for serial communication – see Section on page Connecting to power – see Section on page Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Connecting the Ethernet Ports to the LAN The cabling specifications and procedure for connecting the device to the LAN is as follows: Cable: Straight-through, Category (Cat) 5, 5e or 6 cable Connector: Standard RJ-45 Connector Pinouts: ...
Each port in the Ethernet Group (port pair) must be connected to a different switch (but in the same subnet). √ Ports with the same MAC address (e.g., GE 1-4 ports) must each be connected to a different Layer-2 switch (as the ports share the same MAC address). Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA The following example shows an Ethernet Group comprised of ports 5 and 6, where Port 5 is connected to the main network ("LAN #1") and Port 6 to the redundant network ("LAN #2"). Upon connectivity failure with LAN #1 through Port 5, the device connects to the redundant LAN #2 through Port 6.
Connect the DB-9 connector labeled "P1" (red), at the other end of the cable, to the RS-232 communication port on your computer. Notes: • The RS-232 port is not intended for permanent connection. The DB-9 connector labeled "P2" is used only for debugging. • Survivable Branch Appliance Mediant 2600B SBA...
To install the OSN server modules in the chassis, see Section on page 54. For specifications of the OSN server, including ports and LEDs, see Section 3.2.4 • page 22. Optional drivers for the OSN server modules can be downloaded from AudioCodes • cloud-based server at https://downloads-audiocodes.s3.eu-central- 1.amazonaws.com/Miscellaneous/CP210x_Windows_Drivers_with_Serial_Enumeratio n.zip.
Mediant 2600B SBA Signal Utility/HEAC+ DDC/CEC/HEAC Ground +5 V Power Hot Plug Detect/HEAC 5.3.2 Cabling for Initial Installation of Third-Party Applications Once you have installed an operating system, you can connect to the OSN server in order to install and configure your third-party application (e.g., IP PBX). For this you can connect to the OSN server using the following local connectivity methods: USB and HDMI ports connected to computer peripherals.
The RJ-45 connector pinouts for the Gigabit Ethernet interface are listed in the table below: Table 5-3: RJ-45 Connector Pinouts for Gigabit Ethernet Interface on OSN4 Module 100Base-Tx 1000Base-T Signal Signal Function BI_DA+ BI_DA- BI_DB+ BI_DC+ BI_DC- BI_DB- BI_DD+ BI_DD- Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Connecting to Power The procedure below describes how to connect the device to the power supply. Table 5-4: Power Specifications Item Description Power Supply Two hot swappable, power supply modules for power load sharing and AC power redundancy in case of failure of one of the modules.
Turn on the power at the power source (if required). Check that the POWER LED on each Power Supply module (front panel) is lit green, indicating that the device is receiving power. Survivable Branch Appliance Mediant 2600B SBA...
Page 48
Mediant 2600B SBA This page is intentionally left blank. Hardware Installation Manual Document #: LTRT-39392...
Attach the other end of the wrist strap (e.g., an alligator clip) to the ESD spring screw located on the rear panel of the chassis, as shown below. Figure 6-1: Connecting ESD Wrist Strap to Chassis ESD Lug Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Replacing the SBA CPU Module The procedure below describes how to replace the SBA CPU module. Warning: Before extracting the module, power off the device. To replace the SBA CPU module: Remove the module: Disconnect the power cord from the power sources, and then remove the power cord from the power connections on the two Power Supply modules.
Figure 6-4: Inserting SBA CPU Module Push the module's handle until it clicks firmly in to engage the module with the slot rails. Connect all external interfacing cables to the module, as required. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Installing the MPM Modules The procedure below describes how to install an MPM module into the chassis. Each MPM module occupies two standard AMC slots. Therefore, before installing an MPM module, you need to remove the blank AMC modules covering the slots.
Figure 6-6: Inserting MPM Module Push the module's handle until it clicks firmly in to engage the module with the slot rails. Power up the device. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Installing the OSN Server Modules The procedure below describes how to install the OSN server modules (OSN and HDMX) in the chassis. Warning: Power off the device before installing the OSN modules. Avertissement: Mettez l’appareil hors tension avant d’installer le OSN.
Figure 6-9: Inserting HDMX Module Push the module's handle until it clicks firmly in to engage the module with the slot rails. Power up the device. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Replacing the Fan Tray Modules This section describes how to replace the Fan Tray module. It describes replacement of the Fan Tray module #1 (on left side of chassis), but it also applies to the Fan Tray module The Fan Tray module is hot-swappable and thus, can be replaced without powering down the device.
Fan Tray module to secure the module to the chassis. Verify that the newly installed Fan Tray module is receiving power and operating normally - the PWR LED on the module's front panel should be lit green. Survivable Branch Appliance Mediant 2600B SBA...
Mediant 2600B SBA Replacing the Power Supply Modules This section describes how to replace the Power Supply module. It describes replacement of the Power Supply module #1 (on left side of chassis), but it also applies to the Power Supply module #2.
Using the module's handle, gently push the module into the slot until it has engaged with the chassis backplane. Tighten the two captive screws on the front panel of the module to secure the module to the chassis. You can use a Phillips or flathead screwdriver. Survivable Branch Appliance Mediant 2600B SBA...