Programming Space Cooling - Daikin Altherma EKHVMRD50ABV1 Operation Manual

Table of Contents

Advertisement

Programming space cooling

5 sec
Operation manual
15
Programming space cooling is carried out as follows:
NOTE
1
2
3
4
5
6
7
8
9
10 Use the
11 Repeat steps
5 sec
12 Press the
13 You automatically return to step 5, start again to program the
Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the
button.
Press the
button to enter the programming/consulting mode.
Select the operation mode you would like to program by means
of the
and
buttons.
The actual mode is blinking.
Press the
button to confirm the selected mode.
The time is blinking.
Consult the action by means of the
Hold down the
button for 5 seconds to program the detailed
actions.
The first programmed action appears.
Use the
button to select the action number you would like to
program or to modify.
Use the
and
buttons to set the correct action time.
Use the
and
temperature.
Use the
and
buttons to set the room temperature.
button to select
remote controller off.
6
to
10
to program the other actions.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
button for 5 seconds to store the programmed
actions.
If the
button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 is deleted.
You automatically return to step 5.
By pressing the
button several times, you return to previous
steps in this procedure and finally return to normal operation.
following day.
EKHVMRD50+80ABV1 + EKHVMYD50+80ABV1
and
buttons.
buttons to set the leaving water
to switch cooling and the
Daikin Altherma indoor unit
4P404418-1 – 2015.04