FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Connect the ice machine to cold
WATER INLET
potable water. Use 3/8" O.D. copper
3/8" MALE
tubing, and connect to the 3/8" male
FLARE
flare at the back of the cabinet. Install
a hand valve near the machine to
control the water supply.
Drains
FIELD SUPPLIED
There is one 3/4" FPT drain at the
WATER FILTER
back of the cabinet, the drain line is of
the gravity type, and 1/4 inch per foot
HAND SHUT
OFF VALVE
fall is an acceptable pitch for the drain
tubing. Install a vent at the highest
VENT ICE
point of the drain line, and the ideal
CONNECT TO
MACHINE
drain receptacle would be a trapped
COLD WATER
DRAIN,
and vented floor drain.
3/4" FPT
Use only 3/4" rigid tubing.
Storage Bin: Install a separate
gravity type drain. Insulation of this
drain line is recommended.
VENT BIN DRAIN
3/4" FPT
FLOOR DRAIN
January 2000
Page 9