Anti-legionella heater. In the menu structure the term
"Booster heater" is used. However, this is actually an anti-
legionella heater.
4.10
Installer settings: Tables to be
filled in by installer
4.10.1

Quick wizard

Setting
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
Backup heater steps
BUH type
Forced off contact [A.2.1.6]
Forced off contact
Space heating settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW operation
DHW tank type
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
External kWh meter 2
Capacities (energy metering) [A.2.3]
Anti-legionella heater
BUH: step 1
BUH: step 2
Bottom plate heater
4.10.2

Space heating control

Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Leaving water temperature: Delta T source [A.3.1.3]
Heating
User reference guide
20
Default
Fill in...
0
0 (1P,(1/2))
0 (No)
0 (LWT control)
1 (In room)
1 (1 LWT zone)
1 (Sample)
Depends on
model
Depends on
model
0 (No)
2 (H/C request)
2 (H/C request)
0 (No)
0 (No)
0 (No)
0 (Normally open)
0 (No)
0 (No)
0 (No)
0 (No)
Depends on
model
3 kW
3 kW
0 W
Default
Fill in...
1 (WD)
1 (WD)
5°C
Setting
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
4.10.3

Domestic hot water control [A.4]

Setting
Type
Maximum setpoint
INFORMATION
There is a risk of space heating capacity shortage/comfort
problem (in case of frequent domestic hot water operation,
frequent and long space heating interruption will happen)
when selecting [6‑0D]=0 ([A.4.1] Domestic hot water
Type=Reheat only).
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating and capacity shortage comfort problems is
significant. In case of frequent domestic hot water
operation, frequent and long space heating interruptions
will happen.
4.10.4

Contact/helpdesk number [6.3.2]

Setting
Contact/helpdesk number
5
Setting the energy prices
If your system's savings mode is set to Economical, it allows you to
set:
▪ a fixed fuel price
▪ 3 electricity price levels
▪ a weekly schedule timer for electricity prices.
The savings mode is set by the installer and can be either ecological
or economical. In ecological mode, the primary energy use is
minimised; in economical mode, the running costs. Discuss with the
installer which savings mode is preferred. Refer to the installation
manual for more information.
Example: How to set the energy prices on the user interface?
Price
Fuel: 5.3 euro cent/kWh
Fuel: 4.8 pence/kWh
Electricity: 12 euro cent/kWh
Electricity: 12.49 pence/kWh
5.1

To set the fuel price

1 Go to [7.4.6]:
> User settings > Preset values > Fuel price.
2 Use
and
to set the correct price.
3 Press
to confirm.
EHBH04~16CBV + EHVH04~16S18+26CBV
Default
Fill in...
0 (No)
1 (Slow)
Default
Fill in...
2 (Scheduled
only)
Depends on
model
Default
Fill in...
Value in breadcrumb
[7.4.6]=5.3
[7.4.6]=4.8
[7.4.5.1]=12
[7.4.5.1]=12