Advertisement

Quick Links

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED UNDER AMERICAN NATIONAL STANDARDS: ANSI Z21.11.2 FOR UNVENTED ROOM HEATERS.
CERTIFIED FOR THE UNITED STATES USING ANSI METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
- This is an unvented gas-fi red heater that
uses air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
section " COMBUSTION AND VENTILATION AIR
PROVISIONS".
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
WHVF31N
NATURAL GAS
WHVF31P
WARNING
!
PROPANE
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.23B
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon PLAZMAFIRE WHVF31

  • Page 1 This appliance is not convertible for use with other gases. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com 1.23B...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS 2.1.1 CONVEX SURROUND (S31CV) 2.1.2 RECTANGULAR SURROUND (S31R) GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION COMBUSTION AND VENTILATION AIR PROVISIONS DETERMINING CONFINED OR UNCONFINED SPACE MOUNTING PLATE INSTALLATION MOUNTING THE APPLIANCE GAS INSTALLATION MOBILE HOME MINIMUM CLEARANCE TO COMBUSTIBLES FINISHING...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Mantel, see “MINIMUM CLEARANCES TO COMBUSTIBLES” section. Rating plate, see “RATING PLATE INFORMATION” section. Side Wall Surround, see “FINISHING” section. Side Wall, see “MINIMUM CLEARANCES TO COMBUSTIBLES” section.
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Under no circumstances should this appliance be modifi ed. •...
  • Page 5: Dimensions

    DIMENSIONS 2.1.1 CONVEX SURROUND (S31CV) ” ” ” ” ” ELECTRICAL ” INLET ” INLET ” 2.1.2 RECTANGULAR SURROUND (S31R) ” ” 28” ” ” ” ELECTRICAL ” INLET INLET ” GENERAL INSTRUCTIONS WARNING * CARBON MONOXIDE POISONING MAY LEAD TO DEATH EARLY SIGNS OF CARBON MONOXIDE POISONING RESEMBLE THE FLU, WITH HEADACHE, DIZZINESS AND/OR NAUSEA.
  • Page 6 • Sellers of un-vented propane or natural gas-fi red space / room appliances shall provide to each purchaser a copy of 527 CMR 30.00 upon the sale of the appliance from http://www.napoleonfi replaces.com/ Webshare/installation_manuals/mass_requirements.pdf In absence of local codes, install the appliance to the current National Fuel Gas Code, ANSI Z223.1 Installation Code which can be obtained from: American National Standards Institute Inc.
  • Page 7: General Information

    GENERAL INFORMATION FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! RATES AND EFFICIENCIES NATURAL GAS PROPANE GAS Altitude 0 - 2,000* 0 - 2,000* Maximum Input 20,000 BTU/hr 20,000 BTU/hr Effi ciency 99.9% 99.9% Minimum Inlet Gas Supply Pressure 4.5”...
  • Page 8: Rating Plate Information

    INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. ELECTRICAL RATING: 115V.60HZ. LESS THAN 12 AMPERES MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL (FROM APPLIANCE): MANTEL 20” FLOOR 13” SIDES 7” WOLF STEEL LTD. 24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA SERIAL NUMBER WHVF31 W385-0613 / A...
  • Page 9: Installation

    3.0 INSTALLATION COMBUSTION AND VENTILATION AIR PROVISIONS This appliance shall not be installed in a confi ned space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, ANSI Z223.1 / NFPA 54 defines a confi...
  • Page 10 Without suffi cient fresh air for proper operation, poor fuel combustion can result. Carbon Monoxide is a result of poor combustion. If additional fresh air is required, use one of the methods described in the National Fuel Gas Code, ANSI Z223.1 / NFPA54 or the applicable local code.
  • Page 11: Mounting Plate Installation

    MOUNTING PLATE INSTALLATION Level and affi x the paper template to the wall at desired location and height. The centre line of the template should be located directly between two wall studs. Using the template, mark the holes for the gas and electrical outlets and mounting screws. See “MINIMUM CLEARANCES TO COMBUSTIBLES”...
  • Page 12: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 13: Minimum Clearance To Combustibles

    MINIMUM CLEARANCE TO COMBUSTIBLES The front trims for the WHVF31 are different sizes. See “DIMENSIONS” section prior to mounting the appliance. Clearances are measured from the appliance, not the front trims. MINIMUM CLEARANCES TO COMBUSTIBLES: 20” to top 7” to sides 13”...
  • Page 14: Finishing

    4.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED. 72.4 HOUSING PANEL INSTALLATION Secure the housing panels as illustrated using the 17 #8 X 3/8” screws supplied. - 4 screws secure the top housing panel.
  • Page 15: Door Removal / Installation

    DOOR REMOVAL / INSTALLATION WARNING GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED. FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE.
  • Page 16: Glass Media

    GLASS MEDIA WARNING CLEAN THE GLASS MEDIA PRIOR TO INSTALLATION. BEFORE APPLYING THE CLEANED GLASS, ENSURE THAT IT IS DRY. DO NOT CHANGE OR SUBSTITUTE THE GLASS MEDIA MATERIAL PROVIDED WITH THIS APPLIANCE. IF REPLACING, USE ONLY THE REPLACEMENT GLASS MEDIA AVAILABLE FROM YOUR AUTHORIZED DEALER / DISTRIBUTOR.
  • Page 17: Optional Installation

    5.0 OPTIONAL INSTALLATION SAFETY SCREEN INSTALLATION Remove the 3 screws that secure the door. RETAINING BRACKETS (X3) Place the bottom of the safety screen into the door retainer. Pivot the top of the safety screen to the door frame and secure by using 3 screws to attach the safety screen and door retainer brackets.
  • Page 18: Electrical Information

    6.0 ELECTRICAL INFORMATION WIRING DIAGRAM WARNING DO NOT WIRE 110 VOLTS TO THE VALVE OR WALL SWITCH. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACE WITH A WIRE OF AT LEAST A TEMPERATURE RATING. This appliance comes equipped with a battery back-up.
  • Page 19: Operation

    7.0 OPERATION When lit for the fi rst time, the appliance will emit a slight odour for a few hours. This is a normal temporary con- dition caused by the “burn-in” of internal paints and lubricants used in the manufacturing process and will not occur again.
  • Page 20: Adjustments

    8.0 ADJUSTMENTS VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 21: Maintenance

    9.0 MAINTENANCE MAINTENANCE MAINTENANCE WARNING MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 22: Door Glass Replacement

    DOOR GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 23: Replacements

    COMPONENTS REF NO. PART NO. DESCRIPTION W010-2334 BLACK DOOR FRAME W725-0065 NATURAL GAS VALVE W725-0066 PROPANE GAS VALVE W385-0334 NAPOLEON® LOGO W662-0008 NATURAL GAS PILOT W662-0009 PROPANE PILOT W456-0045 #45 NATURAL GAS ORIFICE W456-0056 #56 PROPANE ORIFICE W300-0142 CRUSHED GLASS...
  • Page 24 ACCESSORIES REF NO. PART NO. DESCRIPTION GD567 SAFETY SCREEN KIT S31RK RECTANGULAR SURROUND - BLACK S31RN RECTANGULAR SURROUND - BROWN S31RP RECTANGULAR SURROUND - PEWTER S31CVK CONVEX SURROUND - BLACK S31CVSS CONVEX SURROUND - STAINLESS STEEL LK31 LED LIGHT KIT W660-0081 THERMOSTAT, WALL MOUNT - DIGITAL ON/OFF REMOTE...
  • Page 25: Troubleshooting

    11.0 TROUBLESHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 26 SYMPTOM PROBLEM TEST SOLUTION Carbon is being Air shutter has become Ensure air shutter opening is free of lint or other deposited on blocked. obstructions. glass, logs, Flame is impinging on the Check that the glass, logs, rocks or media are rocks, media glass, logs, rocks, media correctly positioned.
  • Page 27: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 28: Service History

    13.0 SERVICE HISTORY 43.1...