6

Operation

This section details the operation of the bqStudio software.
6.1
Starting the Program
Run bqStudio from the Start | All Programs | Texas Instruments | Battery Management Studio. The main
screen
(Figure
9) appears. If instead of
is not connected to the computer correctly. Make sure that the USB interface (EV2300 or EV2400 or GDK)
and the bq27531 are connected and restart bqStudio. If this still does not resolve the issue, check if the
I2C pullup resistors are connected. Data begins to appear once the <Refresh> (single-time scan) button is
clicked, or when the Scan button is clicked. To disable the scan feature, simply click the Scan button
again.
The continuous scanning period can be set by opening Window | Preferences → Registers section. The
range for this interval is 0 ms to 65,535 ms. Only items that are selected for scanning are scanned within
this period.
Battery Management Studio provides a logging function which logs the values that were last scanned. To
enable this function, select the Start Log button; this causes the Scan button to be pressed. When logging
is Stopped, the Scan button will still be selected and has to be manually clicked again.
This screen
(Figure
be viewed at the bottom of the Registers screen.
SLUUA90A – April 2013 – Revised July 2016
Submit Documentation Feedback
Figure 9
Figure 9. Registers Screen
9) shows the RAM data in the bq27531 device. Additional Flags and Status data can
bq27531EVM With bq27531 Battery Management Unit Impedance Track™
Fuel Gauge and bq24192 4.5-A, Switch-Mode Battery Charger for Single-Cell
Copyright © 2013–2016, Texas Instruments Incorporated
appearing,
Figure 10
appears, it may mean that the EVM
Operation
17
Applications