3. Determine and mark edge of range in the cutout space. The
mounting bracket can be installed on either the left side or
right side of the cutout. Position mounting bracket in cutout
so that right (or left) edge of the bracket is
the marked edge of the range, as shown.
B
A. Anti-tip bracket
B. Mark edge of range
C.
" (2.4 cm)
15
16
4. Drill two ¹⁄
" (3.0 mm) holes that correspond to the bracket
8
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
A
B
A. #12 x 1
'' screws
5
8
B. Anti-tip bracket
5. Using a Phillips screwdriver, mount anti-tip bracket to the
wall or floor with the two #12 x 1
8
" (2.4 cm) from
¹5
16
A
C
Wall Mounting
A
B
A. #12 x 1
" screws
5
8
B Anti-tip bracket
" screws provided.
5
8

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1.
Apply pipe-joint compound made for use with propane gas
to the smaller thread ends of the flexible connector adapters
(see B and G in the following illustration).
Attach one adapter to the gas pressure regulator and
2.
the other adapter to the gas shutoff valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
3. Use a ¹
" (2.4 cm) combination wrench and an adjustable
5
16
wrench to attach the flexible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas pressure regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn
when tightening the fittings.
H
G
F
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have ½"
(12.7 mm) male pipe thread)
D. Flexible connector
A
B
C
D
E
E. Manual gas shutoff valve
F. ½" or ¾" (12.7 mm or 19 mm)
gas pipe
G. Use pipe-joint compound.
H. Adapter

Advertisement