All parameter clear

4.29 All parameter clear

POINT
· Set "1" in ALLC parameter clear to initialize all parameters. (Parameters are not cleared when "1" is set in Pr. 77
Parameter write selection.)
1.
Screen at powering on
The monitor display appears.
2.
Press
mode.
3.
Press
setting mode.
4.
Turn
clear) appears.
5.
Press
value.
"
"(initial value) appears.
6.
Turn
" ".
7.
Press
Setting
0
Not executed.
All parameters return to the initial values.
1
Refer to the list of parameters on page 436 for availability of all parameter clear.
and
The inverter is not in the PU operation mode.
1. Press
2. Carry out operation from step 6 again.
382
Operation
to choose the PU operation
to choose the parameter
until
(all parameter
to read the currently set
to change it to the setting value
to set.
· Press
to read another parameter.
· Press
to show the setting again.
· Press
twice to show the next parameter.
are displayed alternately ... Why?
.
is lit and the monitor (4 digit LED) displays "0" (Pr. 79 = "0" (initial value)).
Display
PU indication is lit.
Flicker ··· Parameter setting complete!!
Description
The parameter
number read
previously appears.