Lincoln Electric Vantage LE500X Operator's Manual page 9

For use with machines having code numbers: 12883, 12891, 13195, 13196
Table of Contents

Advertisement

VANTAGE
441X/LE500X
®
GENERAL DESCRIPTION
The Vantage
®
441X/LE500X is a diesel engine-driven welding
power source. The machine uses a brush type alternating
current generator for DC multi-purpose welding, for 120/240
VAC single phase and 240 VAC three phase auxiliary standby
power. The welding control system uses state of the art
Chopper Technology
®
.
The machine has been equipped with CrossLinc
provide weld cable communication for voltage control at the arc
without the need for a control cable.
TECHNICAL SPECIFICATIONS
INPUT - DIESEL ENGINE
Make /Model
(K4535-1, K4535-10,
K5174-1, K5174-11)
Perkins
®
404F-E22T EPA
Tier 4 Final Compliant
Speed (RPM)
High Idle 1800
Low Idle 1500
Full Load
Starting System
12 VDC Battery and Starter
with Automatic Glow Plugs
Battery Size
BCI Group Size 34
800 Cold Crank Amps
RATED OUTPUT @ 104°F(40°C) - WELDER
Duty Cycle
Welding Output
400 Amps
100%
(DC multi-purpose)
450 Amps
100%
(DC multi-purpose)
520 Amps
60%
(DC multi-purpose)
IEC 60974-1; IP23 Rated
Technology to
®
Description
4 Cylinder 41.0 HP (30.6 kW)
Turbocharged Water Cooled
Diesel Engine
Displacement
134 cu. in. (2.2L)
Bore x Stroke
3.30" x 3.90"
84mm x 100mm
Capacities
Fuel: 20 US gal. (75.7L)
Oil: 2.50 US gal. (9.5L)
Cooling System: 2.55 US gal.
(9.7L)
Volts at Rated Amps
36 Volts
32 Volts
30 Volts
OUTPUT @ 104°F(40°C) - WELD ER AND GENERATOR
Welding Mode
CC-Stick
Downhill Pipe (CC)
Touch Start TIG
CV-Wire
Arc Gouging
Open Circuit Voltage
60V Avg @ 1800 RPM
70V Peak @ 1800 RPM
Auxiliary Power
120/240 VAC
11,000 Watts, 60 Hz., Single Phase
17,000 Watts, 60 Hz., Three Phase
RECEPTACLES
Receptacle
120 VAC Duplex (5-20R) GFCI Protected
240 VAC Three Phase (15-50R)
120/240 VAC Single Phase (14-50R)
PHYSICAL DIMENSIONS
Height
(2)
Width
(3)
Depth
Weight
(4)
(1) Output rating in watts is equivalent to volt-amperes at unity power factor.
Output voltage is within +/- 10% at all loads up to rated capacity. When weld-
ing, available auxiliary power will be reduced.
(2) Top of Enclosure. Add 6.9" (175 mm) for exhaust.
(3) Includes Door. Base is 27.0" (686 mm) wide.
(4) Approximate weight less fuel.
A-1
INSTALLATION
Output Range
30-525 Amps
40-350 Amps
20-350 Amps
10-45 Volts
60-525 Amps
(1)
Circuit Breaker
20 Amps
50 Amps
50 Amps
39.1 in. (993.7 mm)
28.4 in. (721.0 mm)
65.1 in. (1653.7 mm)
1414 lbs. (641 kg)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage 441x

Table of Contents