STARTING THE GENERATOR (CONTINUED)

Starting the Generator Using Propane

28
1.
Turn breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
2.
Turn gas valve off
The gas valve is located above the recoil start on the
bottom of the fuel tank. Rotate the valve counter clockwise
to the horizontal position to stop the flow of gasoline to the
carburetor.
3.
Connect propane hose
The propane regulator / decompression valve is located
on the frame of the generator below the OHV valve cover.
Ensure the propane hose is securely connected to the
regulator/compression valve.
4.
Connect propane tank
There propane hose is located on the left side of the
regulator, below the OHV valve cover. Screw the open ACME
nut connection to your propane tank and turn the tank on.