Panasonic KX-FP342BX Service Manual page 124

Compact plain paper fax and copier
Table of Contents

Advertisement

KX-FP342BX
NO.
123
RM3/IOP
124
RXE/IOP
125
TMO
126
VDD (2.5V)
127
VSS
128
TM1/IOP
129
TM2/IOP
130
TM3/IOP
131
TXE/IOP
132
KSTART
133
KLATCH
134
KSCLK
135
KTXD
136
KRXD
137
FMEMCLK/IOP
138
FMEMDI/IOP
139
ADSEL1
140
VDDA (2.5V)
141
VREFB
142
VCL
143
VREFT
144
VSSA
7.3.6.
RESET CIRCUIT (WATCH DOG TIMER)
The output signal (reset) from pin 4 of the voltage detect IC (IC507) is input to the ASIC (IC501) 114 and 106 pins.
1. During a momentary power interruption, a positive reset pulse of 50~70 msec is generated and the system is reset completely.
2. The watch dog timer, built-in the ASIC (IC501), is initialized by the CPU about every 1.5 ms.
When a watch dog error occurs, pin 115 of the ASIC (IC501) becomes low level.
The terminal of the ´WDERR´ signal is connected to the reset line, so the ´WDERR´ signal works as the reset signal.
SIGNAL
I/O
O
O
O
O
O
O
O
O
O
O
O
I
O
O
O
A
A
A
POWER SUPPLIED
VOLTAGE
3.3V
RX MOTOR /B PHASE
3.3V
RX MOTOR ENABLE SIGNAL
3.3V
TX MOTOR A PHASE
3.3V
POWER SOURCE (+2.5V)
GND
POWER SOURCE (GND)
3.3V
TX MOTOR B PHASE
3.3V
TX MOTOR /A PHASE
3.3V
TX MOTOR /B PHASE
3.3V
TX MOTOR ENABLE SIGNAL
3.3V
OPERATION PANEL CONTROL
3.3V
OPERATION PANEL CONTROL
3.3V
OPERATION PANEL CONTROL
3.3V
OPERATION PANEL CONTROL
3.3V
OPERATION PANEL CONTROL
3.3V
OUTPUT PORT (THON)
3.3V
OUTPUT PORT (LINERLY)
3.3V
CHANNEL SELECT SIGNAL FOR AIN2
3.3V
POWER SOURCE (ANALOG +2.5V)
2.5V
A/D CONVERTER´S ZERO STANDARD VOLTAGE
OUTPUT
3.3V
ANALOG PART STANDARD VOLTAGE SIGNAL
3.3V
A/D
CONVERTER´S
OUTPUT
GND
POWER SOURCE (ANALOG GND)