Wiring Diagrams - Broan InVent AE80S Installation And Use & Care Instructions

Humidity sensing fan
Hide thumbs Also See for InVent AE80S:
Table of Contents

Advertisement

Available languages

Available languages

WIRING DIAGRAMS

WIRING OPTION #1
When switch is ON, fan will operate automatical-
ly, based on room humidity conditions.
Turn fan ON immediately for the set timer period
(to control odors), by cycling switch.
ON / OFF SWITCH
(PURCHASE SEPARATELY)
ON / OFF
SWITCH
BLK
120
WHT
VAC
LINE
GRD
IN
SWITCH BOX
MODELS AE80S, AE110S
SERVICE PARTS
Key No.
Part No.
1
97019514 Housing
97019561
2
97020122
3
97020536 Wire Panel Assembly
4
97020538 Humidity Control Panel Assembly
97019785
5
97019786
6
99140214 Grille Spring (2 req.)
7
97019781 Grille Assembly (includes key no. 6)
97019743 Parts Bag (not shown)
8
GREY
BLK
BLK
BRN
HUMIDITY
CONTROL
WHT
GRD
UNIT
Description
Duct Connector - 4-in. (AE80S)
Duct Connector - 4-in. (AE110S)
Blower Assembly (AE80S)
Blower Assembly (AE110S)
WIRING OPTION #2
When first switch (1) is ON, fan will operate auto-
matically based on room humidity conditions.
Turn fan ON immediately (to control odors) by using
second switch (2).
2-FUNCTION CONTROL
(PURCHASE SEPARATELY)
(2)
FAN
WHT
(ON/OFF)
FAN
COM
WHT
(1)
HUMIDITY
WHT
CONTROL
(AUTO/OFF)
BLK
120
WHT
VAC
LINE
GRD
IN
SWITCH BOX
RED
GREY
HUMIDITY
CONTROL
BLK
BRN
WHT
GRD
2
3
7
BLK
WHT
FAN
WHT
WHT
UNIT
1
4
5
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invent ae110s

Table of Contents