4.
5.
6.
When the HI is changed, the Z coordinate is updated before the station is recorded. You must complete a station
setup before you use the Remote Benchmark function.
Checking and resetting the backsight direction
You must complete a station setup before you use the BS check function.
This function always refers to the backsight point from the last ST record stored in the current open job.
1.
HA
BS
2.
Sight the BM point and press
Press [ENT].
.
The updated station coordinates are displayed.
You can change the HI in this screen.
To record the updated STN, press
To enter the backsight (BS) check function,
BS Check
press
or select
[5]
menu.
Current HA reading
The HA to the BS in the last station setup. Enter
station coordinates for observations without recording
data.
Do one of the following:
To reset the horizontal angle to the HA set in the last station setup sight the
–
BS and press the
To cancel the process and return to the BMS, press the
–
press
.
[ESC]
or
[MSR1]
[MSR2]
.
[ENT]
in the Stn Setup
Reset
softkey or press
Total Station DTM-322 Instruction Manual
.
.
[ENT]
Abrt
Applications 4
softkey or
5 7