MOUNTING AND WIRING THE SAFETY SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot
on each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other
across the door. Be sure the lens is not obstructed
by a bracket extension. See Figure 4.
• Finger tighten the wing nuts.
• Run the wires from both sensors to the opener. Use
insulated staples to secure wire to wall and ceiling.
• Strip 1/4" of insulation from each set of wires.
Separate white and white/black wires sufficiently to
connect to the opener terminal screws: white to 2
and white/black to 3. See Figure 5.

ALIGNING THE SAFETY SENSORS

• Plug in the opener. The indicator lights in both the
sending and receiving eyes will glow steadily if
wiring connections and alignment are correct.
The sending eye orange indicator light will glow
regardless of alignment or obstruction. If the green
indicator light in the receiving eye is off, dim, or
flickering (and the invisible light beam path is not
obstructed), alignment is required.
• Loosen the sending eye wing nut and readjust,
aiming directly at the receiving eye. Lock in place.
• Loosen the receiving eye wing nut and adjust
sensor until it receives the sender's beam. When
the green indicator light glows steadily, tighten the
wing nut.
Figure 5
Bell Wire
Invisible Light Beam
Sensor
Protection Area
Figure 4
1. If the sending eye indicator light does not glow
2. If the sending eye indicator light glows steadily but
3. If the receiving eye indicator light is dim, realign
NOTE: When the invisible beam path is obstructed
or misaligned while the door is closing, the door will
reverse. If the door is already open, it will not close.
The opener lights will blink 10 times. (If bulbs are not
installed, 10 clicks can be heard.) See page 17.
Finished
Ceiling
Bell Wire
Sensor
19
1/4"-20x1/2"
Carriage bolt
TROUBLESHOOTING THE SAFETY SENSORS
steadily after installation, check for:
• Electric power to the opener.
• A short in the white or white/black wires. These
can occur at staples, or at screw terminal
connections.
• Incorrect wiring between sensors and opener.
• A broken wire.
the receiving eye indicator light doesn't:
• Check alignment.
• Check for an open wire to the receiving eye.
either sensor.
Connect Wire to
Opener Terminal Screws
Door Control
Connections
(dotted line)
1
OPENER TERMINAL SCREWS
Wing nut
Lens
Sensor
Connections
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents