TLC3-BCR-U Series Thermostat
Applications
Radiant heating
Radiant cooling
General
TLC3-BCR-U: 1 independent temperature control loop with 1 heating and 1 cooling sequence. 1 internal
temperature sensor, 1 external temperature input, 1 auxiliary input for heat – cool changeover or high/low
limit
Flexible application configuration is made with a parameter-setting routine using the standard operation
terminal.
Name
- B
T
L
C
3
C
Ordering
Model
TLC3-BCR-U-230
TLC3-BCR-U-230-W01
TLC3-BCR-U-D-230
TLC3-BCR-U-D-230-W01
Temperature sensors: Use Vector Controls NTC sensors to achieve maximum accuracy: SDB-Tn10-20 (duct), SRA-
Tn10 (room), SDB-Tn10-20 + AMI-S10 as immersion sensor.
Binary auxiliary devices (e.g. pumps, fans, on/off valves, etc): Do not directly connect devices that exceed specified
limits in technical specifications – observe startup current on inductive loads.
Doc: 70-00-0294, V3.1, Date: 20140508
Subject to alteration
Features
TLC3-BCR-U-D also includes
Small air handlers
Constant air
volume systems
-
R
U
Voltage:
Housing
Outputs:
Control:
Series:
Item code
Variation
Standard
40-10 0160
Cooling only
40-10 0160-01
Deluxe
40-10 0161
Cooling only
40-10 0161-01
© Vector Controls GmbH, Switzerland
Low power energy consumption: < 1W per unit
Relays switching for outputs each up to 300W
Temperature control for 2 or 4-pipe heating or cooling
systems.
Optional external temperature input
Choose between one 3-point actuator and two binary
heating/cooling stages
Reversing valve options
New with V3.1 dual stage option
Cost saving option with Economy functionality and set
point limitations
Multiple auxiliary functions: heat-cool auto changeover,
automatic enable, high or low limits.
Password protected programmable user and control
parameters.
Power Cap protected real-time clock with 48hr power
backup.
Time schedule events, with many options.
Blue backlight.
Frost protection
Blank = 230V, 0 = 24V, 1 = 120V
Blank = square housing, U = 2x4" housing
R = Relays
BC = Binary Control, FC = Fan Coil control
TLC3
Binary controller with:
1 RT int, 2 RT ext
2 DO (Relay) Binary valve control
TLC3-BCR-U Thermostat
O
VERVIEW
General
temperature
control
Option
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Vector TLC3-BCR-U Series

  • Page 1 Cooling only 40-10 0161-01 Temperature sensors: Use Vector Controls NTC sensors to achieve maximum accuracy: SDB-Tn10-20 (duct), SRA- Tn10 (room), SDB-Tn10-20 + AMI-S10 as immersion sensor. Binary auxiliary devices (e.g. pumps, fans, on/off valves, etc): Do not directly connect devices that exceed specified limits in technical specifications –...
  • Page 2: Operation

    60 x 50 x 32mm (2.4 x 2.0 x 1.3 in.) Distance for mounting screws: Horizontal 55 to 60mm (2.2 to 2.4 in.) Vertical: 55 to 93mm (2.2 to 3.7 in.) Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 2 Subject to alteration...
  • Page 3: Mounting Location

    With a Philips-type screw driver of size #2, carefully tighten the front holding screw to secure the front part to the mounting plate. This screw is located on the front lower side of the unit. There is no need to tighten the screw too much. Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 3 Subject to alteration...
  • Page 4: Display And Operation

    Error temperature sensor. The internal temperature sensor may be damaged or not present Steady: Frost protection is active. Blinking: Frost protection activated in the past and is now inactive. Confirm with OPTION key. Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 4 Subject to alteration...
  • Page 5: Clock Operation

    Repeat steps 4 and 5 for all 4 switching events. In case a switching event is not used, set its mode to “no”. Pr01 08:00 To review the entire schedule group, step through by repeatedly pressing the OPTION key from step 1 onwards to step 6. Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 5 Subject to alteration...
  • Page 6 Press the POWER to leave the menu. The unit will return to normal operation if no button is pressed for more than 5 minutes Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 6 Subject to alteration...
  • Page 7: User Configuration

    = Reset of override mode is not active. 1…255 = delay in minutes to switch off device if ON/Economy mode is activated while the unit is scheduled to be in OFF mode Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 7 Subject to alteration...
  • Page 8: Control Configuration

    Dead zone h/c set points Economy mode set point shift Set point heating/reverse Set point cooling/direct T [°C, F] PI sequence heating/reverse U [V, mA] PI sequence cooling/direct Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 8 Subject to alteration...
  • Page 9 Rev valve (in heat mode) 4-pipe reversing valve on Cool Stage 1 Rev valve (in cool mode) 2-pipe system heat of cool, 2 stages Stage 1 Stage 2 Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 9 Subject to alteration...
  • Page 10 Dry contact: OFF if contact closed CP19 < CP20 -40°C (-40F) 45°C (59F) Dry contact: OFF if contact open CP19 < CP20 15°C (59F) 80°C (176F) Doc: 70-00-0294, V3.1, Date: 20140508 © Vector Controls GmbH, Switzerland Page 10 Subject to alteration...