Instructions for the installer
2.4 Discharge of combustion products
Discharge of combustion products must be guaranteed by means of
hoods connected to a natural draught flue with certain efficiency, or by
means of forced aspiration.
An efficient aspiration system requires careful planning by a specialist
capable of installing it, respecting the positions and distances prescribed
by standards. After installation, the installer must issue a certificate of
conformity.

3. GAS CONNECTION

This appliance is suitable for installation with Natural
Gas or ULPG (propane). Refer to page 12 for the
relevant burner pressure and appropriate injector
sizes. When the appliance is to be connected to
Natural Gas then the pressure regulator supplied must
be fitted to the gas inlet. A test point (for checking the
gas pressure) is supplied either with the regulator or as
a separate fitting in the case of ULPG (propane)
appliances.
Connection of the appliance to the gas supply must be
in accordance with the requirements of AS5601. A ½"
BSP connector at the inlet is recommended and the
gas supply line to the appliance must be of adequate
length to allow sufficient withdrawal of appliance for
service or disconnection and be:
1.
annealed copper pipe or;
2.
flexible hose according to AS/NZ1869 & be at
least Class "B", 10 mm diameter.

Advertisement