Frigidaire FFHP094WS1 Installation Manual page 10

Split type room air conditioner
Table of Contents

Advertisement

Indoor unit outline
6" or more
from the wall
Refrigerant pipe
hole (right) Ø 2.56"
Installing the Wall Mounting Bracket
1. Install the wall mounting bracket
horizontally over the structural
parts on the wall using the spaces
indicated on the bracket, as shown
in figure 1.3.
2. In the case of tiled, concrete or
similar walls, create 13/64"
diameter holes. Place anchor
supports for the appropriate
assembly screws.
3. Install the wall mounting bracket to
Attention!!!
Fit the wall mounting bracket and drill holes in the wall according to the
wall structure and corresponding mounting points on the wall mounting
bracket (Dimensions are in "inches" unless otherwise stated).
Drilling the Hole
1. Determine the position of the
hole for the pipes using the wall
mounting bracket and drill the
pipe hole so that it is tilted slightly
downward.
2. Always use a pipe cover with an
opening when drilling.
Indoor unit installation
09
6" or more from
the ceiling
1.97''
3.94''
≥28000 Btu's (A:53.15" B:12.83")
Wall mounting bracket
A
the wall with eight A type screws.
4. At all times securing to the wall
studs is recommended.
Wall mounting bracket
Figure 1.3
Wall
Indoor unit
6" or more
from the wall
1.97''
Refrigerant pipe
hole (right) Ø 2.56"
4.88''
Outdoor unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ffhp124ws1Ffhp124cs1