LINED MASONRY CHIMNEY INSTRUCTIONS &
DIAGRAM
This stove is designed to be vented through a masonry
chimney which conforms to local building codes, fire
codes, and latest edition of NFPA 21 1 US or CAN/
CSA-B365.
1. If the connection piping from the stove to a
masonry chimney is made through a combustible
wall, consult a qualified mason or chimney dealer
for consultation. To ensure safety, the installation
should only be done by a qualified installer. The
installation must conform to the regulations
established by local fire codes and building codes
2. The chimney connection
the chimney connector pipes, such as the figure
below illustrates.
Correct
Figure 12
Connection Pipe & Chimney Connection
3. If there is an opening at the base of the chimney it
must be closed tightly.
MANUFACTURED CHIMNEY INSTRUCTIONS &
DIAGRAM
WARNING: DO NOT USE SINGLE-WALL
CONNECTION PIPE AS A CHIMNEY.
This stove is designed to be used with either a UL
103HT (US)/ULC-S629 (CAN) listed manufactured
chimney or an approved lined masonry chimney. Not
all manufactured chimney are UL103 HT/ULC-S629
listed. Home centers, hardware stores, HVAC
supply stores, and the Online websites of chimney
manufacturers will be able to provide stove pipe that is
rated to these standards.
This listing indicates that the Chimney is rated for high
temperatures up to 2100 °F (1 149 °C)
Only use components that all come from the same
manufacturer. Do not mix brands of components for
the same ventilation system.
The following figures illustrate various methods and
requirements of using a manufactured chimney and
connection pipes to vent the stove.
Grand Teton Wood Pellet Fire Stove
must not be obstructed by
Wrong
Wrong
Double-wall UL 103
Double-wall UL 103
High Temperature
High Temperature
Chimney Pipe
Chimney Pipe
12
Floor
Floor Protector
Protector
Figure 13
Manufactured Chimney through Wall
UL 103 Chimney
UL 103 Chimney
Joist Shield
Joist Shield/Firestop
/ Firestop
Chimney Support
Chimney Support
Double-wall UL 103 High
Double-wall UL 103 High
Temperature Chimney Pipe
Temperature Chimney Pipe
Floor
Floor
Protector
Protector
Figure 14
Manufactured Chimney through Attic
12
Operating Instructions and Owner's Manual
Wall
Termination
Termination
Wall Thimble
Thimble
Cap
Cap
6 in
6 in
(152mm)
(152mm)
Minimum
Minimum
6 in
6 in
(152mm)
(152mm)
Minimum
Minimum
Horizontal
Horizontal
Termination
Termination
Clean Out T
Clean Out T
Cap
Cap
Mandatory Chimney Cap &
Mandatory Chimney Cap &
Spark Arrestor
Spark Arrestor
Storm Collar & Roof
Storm Collar & Roof
Flashing per Local
Flashing per Local
Mobile Home Building
Mobile Home Building
Codes
Codes
Attic Insulation
Attic Insulation
Shield
Shield
Clean Out T
Clean Out T
Bolted to Floor
Bolted to floor