General information

HOOD EXHAUST

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to
recirculate the air back into the room, proceed to page 11.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Roof Cap
12 Ft. Straight Duct
(6˝ Round)
Rectangular-to-
Round Transition
Adaptor*
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be
cut to fit, using the tin snips, in order to allow free movement of the damper.
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
The following chart contains an example of one possible ductwork installation.
DUCT PIECES
Wall Cap
3 Ft. Straight Duct (3 ¼˝
x 10˝ Rectangular)
90 ° Elbow
Equivalent lengths of duct pieces are based on actual tests
and reflect requirements for good venting performance with
any vent hood.
NOTE: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should be
prepared at the time it is constructed by leaving enough space between the wall studs to accommodate the exhaust duct.
Manual-Installation_MC17J8100CS_AC_DE68-04129B-02_EN+CFR.indb 4
EQUIVALENT
NUMBER
x
LENGTH
USED
24 ft.
x
12 ft.
x
5 ft.
x
Total Length
EQUIVALENT
NUMBER
x
LENGTH
USED
40 ft.
x
3 ft.
x
10 ft.
x
Total Length
4
EQUIVALENT
=
LENGTH
(1)
=
24 ft.
(1)
=
12 ft.
(1)
=
5 ft.
=
41 ft.
EQUIVALENT
=
LENGTH
(1)
=
40 ft.
(1)
=
3 ft.
(2)
=
20 ft.
=
63 ft.