1-4-4 Warm air blowing section (Multi purpose feeder only)
(1) Detaching and refitting the PF heater PWB
Procedure
1. Remove the cassette.
2. Remove two screws.
3. Insert a flat-blade screwdriver into the
cutout and release two hooks.
4. Turn the paper feeder with the bottom
side up.
5. Release two hooks and then remove
the fan cover.
All manuals and user guides at all-guides.com
Hook
Hook
1-4-8
Hole
Screw
Screw
Figure 1-4-11
Hook
Figure 1-4-12
3M9/3NA
Hole
Hook
Fan cover