en Cleaning and servicing
Cleaning the drain pump
Note: Please read the information in
the "Safety" → Page 4 and "Prevent-
ing material damage" → Page 11 sec-
tions to ensure that you use the appli-
ance safely.
Requirement: "The drain pump is
empty." → Page 48
Since water may remain in the
1.
drain pump, remove the pump cap
carefully.
Clean the interior, the thread on
2.
the pump cap and the pump hous-
ing.
Make sure that the impeller in the
3.
drain pump can be rotated.
Insert the maintenance flap and
4.
lock it into place.
Close the maintenance flap.
5.
Cleaning the water outlet
hose at the siphon
If the water outlet hose at the siphon
is dirty or the detergent solution is
not being pumped out, you must
clean these.
Switch off the appliance.
1.
Disconnect the appliance's mains
2.
plug from the power supply.
50
Loosen the hose clamp and care-
3.
fully remove the water outlet hose.
Residual water may leak out.
Clean the water outlet hose and si-
4.
phon connecting piece.
Reattach the water outlet hose and
5.
secure the connection point using
the hose clamp.