Safety Check after Servicing
Examine the area surrounding the repaired location for
damage or deterioration. Observe that screws, parts,
and wires have been returned to their original positions.
Afterwards, do the following tests and confirm the spec-
ified values to verify compliance with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d') between sol-
dered terminals, and between terminals and surround-
ing metallic parts. (See Fig. 1)
Table 1: Ratings for selected area
AC Line Voltage
Clearance Distance (d), (d')
120 V
Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current
between B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals,
antenna terminals, video and audio input and output
terminals, microphone jacks, earphone jacks, etc.) is
lower than or equal to the specified value in the table
below.
Measuring Method (Power ON) :
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC volt-
meter to measure across the terminals of load Z. See
Fig. 2 and the following table.
Table 2: Leakage current ratings for selected areas
AC Line Voltage
120 V
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
3.2mm (0.126 inches)
Load Z
0.15µF CAP. & 1.5kΩ RES.
Connected in parallel
Chassis or Secondary Conductor
Primary Circuit Terminals
d'
Exposed Accessible Part
Z
1.5k
0.15 F
Earth Ground
B
Power Cord Plug Prongs
Leakage Current (i)
i≤0.5mA Peak
6
DVD-1910/755
d
Fig. 1
AC Voltmeter
(High Impedance)
Fig. 2
Earth Ground (B) to:
Exposed accessible parts