Intelia Focus And Class Test Mode - Philips Saeco INTELIA Service Manual

Table of Contents

Advertisement

INTELIA-INTUITA
5.1.2.
To enter Test Mode
1. Hold down the Espresso and
Menu buttons.
2. Switch on the main switch at
the back of the machine.
Entry into Test Mode results in a screen divided into sections, as illustrated in the diagram below.
Press STAND_BY "
ERROR condition:
The letters do not change from N to Y or are always Y, in this case check the flat communication
cable with the power board -Power JP21, if it does not change color check the cable JP4 between
the board and the display.
Press STAND_BY "
If you insert a full drip tray the TANK-H20 indicator must change from "N" to "Y".
ERROR condition:
If the indication does not change, check the capacitive sensor and relative wiring
(JP23).

Intelia Focus and Class Test mode

Firmware Software version
Shows the version of the firmware loaded for Focus and Class.
" to move to the next screen
Operational check – keys
Initial status
The letter next to it changes from N to Y only when a button is pressed.
By pressing buttons 1, 3, 4, 6 the display color changes from GREEN to RED.
By pressing buttons 2, 5, the display color changes from GREEN to YELLOW.
Button 4 must be pressed at the end only once as when pressed it moves to
the next page.
" to move to the next screen
Operational check microswitches and sensors
Initial status.
05 SERVICE MODE
1
2
6/22

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saeco intuita

Table of Contents