Installing the Pre-plumbed Mono Cylinder

Installing the pre-plumbed mono cylinder
When you order the pre-plumbed cylinder, it comes with an FTC, the tank sensor, flow and return sensors and
controller all installed for you.
Install the pre-plumb indoors, it's not waterproof. It needs to be sited within 15m of the outdoor unit.
Model Type
Standard
Standard
Standard
Standard
Standard
Solar
Solar
Solar
Slimline
Slimline
The Pre-plumbed Cylinder
Heating Return
02380 274 833 | sales@freedomhp.co.uk
Installation Manual.indd 9
Nominal
Weight of full
Capacity (litres)
unit (kg)
150
206
170
232
210
279
250
327
300
387
210
284
250
332
300
392
150
204
170
230
Flow from HP
Boiler Flow
Return to HP
Primary pump
pumps water to the
outdoor unit and back
Boiler Return
Heating Flow
Standing Heat Loss
Weight of unit
per day
(kg)
(kWh/24h)
56
1.19
62
1.32
69
1.57
77
1.67
87
1.89
74
1.56
82
1.63
92
1.84
54
1.45
60
1.63
G3 kit already installed.
It comes with a white
expansion vessel in the kit
Hot water pump and plate
hex. The cylinder has no coil
inside, the potable water is
pumped through the plate by
this pump. There is also a
de-scaler in line.
per year
(kWh/365d)
434.4
481.8
573.1
609.6
689.9
569.4
595.0
671.6
529.3
595.0
9
27/10/2019 15:13:58