2.3

Wiring

1.
For the wiring, strip off the sheath of a cable, and use it with a crimp terminal. For a single wire, strip off the sheath of the
wire and apply directly. Insert the crimp terminal or the single wire into a socket of the terminal.
Strip off the sheath as shown below. If too much of the wires is stripped, a short circuit may occur with neighboring wires.
If not enough of the wire is stripped, wires may become loose and fall out.
Twist the stripped end of wires to prevent them from fraying. Do not solder them.
Crimp the terminals on the wire.
Insert the wire into a crimp terminal, making sure that 0 to 0.5 mm of the wire protrudes from the end of the sleeve.
Check the condition of the crimp terminals after crimping. Do not use the crimp terminals of which the crimping is
inappropriate, or the face is damaged.
CAUTION
• After wiring, wire offcuts must not be left in the inverter. They may cause a fault, failure or malfunction.
18
INSTALLATION
Cable sheath stripping length
10mm
Damaged
Wires are not inserted
Crumpled tip
into the sleeve
Unstranded
wires