60 Hz - Atlas Copco LE2 Instruction Book

Hide thumbs Also See for LE2:
Table of Contents

Advertisement

Instruction book

7.3.2 60 Hz

Compressor type
Maximum working pressure for LE
Maximum working pressure for LE
Trolley
Pre-set pressure difference for LE
Trolley
Temperature at outlet valve,
approx.
- Unsilenced compressor
- Silenced compressor
Power input at max. working
pressure
Motor shaft speed
Free air delivery 2)
Oil capacity
Opening pressure of safety valve
(not for Block/Power Pack)
Maximum sound pressure level 1):
-Standard version
-Silenced Tank-mounted version
-Base-mounted version
2920 1585 00
LE2
LE3
bar(e)
10
10
bar(e)
9.5
9.5
bar
1
1
°C
49
54
°C
57
62
kW
2.36
3.38
r/min
1800
1800
l/s
3.9
5.1
l
0.8
0.8
bar(e)
11
11
dB(A)
80
81
dB(A)
67
68
dB(A)
65
66
- 65 -
LE5
LE7
LE10
10
10
10
9.5
9.5
9.5
1
1
1
80
74
59
88
82
67
6.36
7.57
9.97
1800
1800
1800
9.7
13.6
17.4
0.8
1.4
1.7
11
11
11
81
82
83
68
72
74
66
70
70
LE15
LE20
10
10
9.5
9.5
1
1
67
127
75
135
12.83
17.87
1800
1800
21.9
28.2
1.7
1.7
11
11
84
85
75
75
72
73

Hide quick links: