Summary of Contents for Panasonic S-M20PY3E

  • Page 1 Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 4-Way Cassette 60 × 60 (Type Y3) Model No. INDOOR UNIT 4-Way Cassette 60 × 60 (Type Y3) S-M20PY3E S-25PY3E S-36PY3E S-50PY3E S-60PY3E OUTDOOR UNIT Single Split See page 12.
  • Page 2: Table Of Contents

    Safety Precautions Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached. Contents The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or...
  • Page 3 WARNING If the refrigerant comes in contact Do not use modified with a flame, it produces toxic cord, joint cord, gases. extension cord or unspecified cord to prevent For safety, be sure to turn the overheating and fire. air conditioner off and also to disconnect the power before cleaning or servicing. The appliance shall be stored Pull off the power plug from in a room without continuously a receptacle, or switch off...
  • Page 4 WARNING CAUTION This appliance is intended to be used by The appliance shall be stored expert or trained users in shops, in light in a room without continuously industry and on farms, or for commercial operating open flames (for use by lay persons. example: an operating gas This appliance is not intended for use appliance) and ignition sources...
  • Page 5: Precautions For Use

    Precautions for Use Installation Disposal of Old Equipment Only for European Union and countries with This air conditioner must be installed properly by qualified recycling systems installation technicians in accordance with the Installation This symbol on the products, packaging, and/ Instructions provided with the unit. or accompanying documents means that used Before installation, check that the voltage of the electric electrical and electronic products must not be supply in your home or office is the same as the voltage...
  • Page 6: Names Of Parts

    Names of Parts INDOOR UNIT Label Type Y3 (attached to the lid of electrical component box) Air intake grille This air conditioner incorporates a biocidal product. (air intake) Ionized air generated by a device incorporated in the air conditioner deactivates bacteria and viruses in the air, and on surfaces, and inhibits mould growth on surfaces.
  • Page 7: Maintenance

    Maintenance „ Indoor unit WARNING (e.g. Type Y3) Air outlet For safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may Air intake result because the fan is rotating at high speed.) Do not pour water on the indoor unit.
  • Page 8: Nanoe™ X Function

    nanoe™ X Function Display during operation of nanoe™ X Example: Initial screen of remote controller CZ-RTC5B CZ-RTC6 series room A 20:30 (THU) SET TEMP. MODE FAN SPEED COOL °C °C FLAP : Under operation of nanoe™ X : Under operation of nanoe™ X nanoe™...
  • Page 9 X function. If you wish to set the internal cleaning function to OFF with CZ-RTC6 series remote controller, use Panasonic H & C Control App. This app is compatible with the following remote controllers. Check the model number shown in the label on the bottom of the remote controllers.
  • Page 10: Troubleshooting

    Troubleshooting Check before consulting or requesting services. Symptom Cause / Action Sound like streaming water is heard • Sound of refrigerant liquid flowing inside unit during operation or after operation. • Sound of drainage water through drain pipe Noise Cracking noise is heard during operation • Sound due to temperature changes of parts or when operation stops.
  • Page 11: Before Requesting Services

    Before Requesting Services Symptom Cause Action The air Power failure or after power failure Press the power ON/OFF button on the remote controller. conditioner does • If the breaker is turned off, turn the power on. not operate The operation (power) button is turned off. • If the breaker has been tripped, consult your dealer although the without turning it on.
  • Page 12 Connectable outdoor unit lineup When connecting RAC Multi outdoor unit, see Section “Supplement” as well. Europe „ Refrigerant type : R32 Outdoor unit type 1-phase U-36PZH2E5 – U-50PZH2E5 – PZH2 3-phase – – – – 1-phase – – – – 3-phase – – – – Outdoor unit type 1-phase U-71PZH2E5 U-100PZH2E5 U-125PZH2E5 U-140PZH2E5...
  • Page 13: Specifications

    Specifications When connecting RAC Multi outdoor unit, see Section “Supplement” as well. Indoor unit 4-Way Cassette 60 × 60 (Type Y3) Model Name S-25PY3E S-36PY3E S-50PY3E S-60PY3E Power source (Europe) 220 - 230 - 240 V~ 50 Hz Power source (Oceania) 230 - 240 V~ 50 Hz Cooling capacity 8,500 12,300 17,100 20,500...
  • Page 14: Outdoor Unit

    Specifications When connecting RAC Multi outdoor unit, see Section “Supplement” as well. Outdoor unit Single Split Outdoor Unit (R32) Model Name U-36PZH2E5 U-50PZH2E5 Europe Power source 220 - 230 - 240 V~ 50 Hz Cooling capacity 12,300 17,100 BTU/h Heating capacity 13,600 19,100 BTU/h Sound pressure level 43 / 44 45 / 48 dB(A) (Cooling / Heating)
  • Page 15 Model Name U-100PZ2E5 U-100PZ2E8 Europe Power source 220 - 230 - 240 V~ 50 Hz 380 - 400 - 415 V 3N~ 50 Hz 10.0 10.0 Cooling capacity 34,100 34,100 BTU/h 10.0 10.0 Heating capacity 34,100 34,100 BTU/h Sound pressure level 52 / 52 52 / 52 dB(A)
  • Page 16 Specifications When connecting RAC Multi outdoor unit, see Section “Supplement” as well. Outdoor unit Single Split Outdoor Unit (R32) Model Name U-36PZH3E5 U-50PZH3E5 U-60PZH3E5 Europe Power source 220 - 230 - 240 V~ 50 Hz Cooling capacity 12,300 17,100 20,500 BTU/h Heating capacity 13,600 19,100 23,900 BTU/h Sound pressure level 43 / 44 46 / 48 47 / 50...
  • Page 17 Model Name U-25PZ3E5 U-36PZ3E5 U-50PZ3E5 U-60PZ3E5A Europe Power source 220 - 230 - 240 V~ 50 Hz Cooling capacity 8,500 12,300 17,100 20,500 BTU/h Heating capacity 10,900 12,300 17,100 20,500 BTU/h Sound pressure level 46 / 47 46 / 47 46 / 46 47 / 48 dB(A)
  • Page 18 Specifications When connecting RAC Multi outdoor unit, see Section “Supplement” as well. Outdoor unit Single Split Outdoor Unit (R32) Model Name U-25PZ3R5 U-36PZ3R5 U-50PZ3R5 U-60PZ3R5 Oceania Power source 230 - 240 V~ 50 Hz Cooling capacity 8,500 12,300 17,100 20,500 BTU/h Heating capacity 10,900 12,300 17,100 20,500 BTU/h Sound pressure level 48 / 49 48 / 49 48 / 49...
  • Page 19: Supplement

    Supplement When connecting RAC Multi outdoor unit (Refrigerant type : R32), see the follow section as well. „ Names of Parts RAC MULTI OUTDOOR UNIT 2 ROOM MULTI 3 ROOM MULTI 4 ROOM MULTI (Type 35, 41, 50) (Type 52, 68) (Type 80) 4 ROOM MULTI 5 ROOM MULTI...
  • Page 20 Supplement „ Specifications Multi Split Indoor Unit Model S-M20PY3E S-25PY3E S-36PY3E S-50PY3E S-60PY3E (Capacity) (2.0 kW class) (2.5 kW class) (3.5 kW class) (5.0 kW class) (6.0 kW class) Power Source Single phase, 230 V, 50 Hz Sound pressure level (acc. to JIS C 9612 COOL [<70 dB(A)]);...
  • Page 21 Supplement „ Specifications Multi Split Outdoor Unit Model CU-2Z35TBE CU-2Z41TBE CU-2Z50TBE CU-3Z52TBE Standard Indoor Unit (1.6 kW + 1.6 kW Combination (1.6 kW + 2.0 kW) (1.6 kW + 2.5 kW) (2.5 kW + 2.5 kW) + 2.0 kW) (wall mounted) (Capacity) Power Source Single phase, 230 V, 50 Hz...
  • Page 22 Contact in the UK Panasonic UK, a branch of Panasonic Marketing Europe GmbH, Maxis 2, Western Road, Bracknell, Berkshire, RG12 1RT Panasonic Corporation Authorised representative in EU http://www.panasonic.com Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany ©...