Repair

Preventive Maintenance
Schedule
The operating conditions of your system determine how
often maintenance is required. Establish a preventive
maintenance schedule by recording when and what kind
of maintenance is needed, and then determine a regular
schedule for checking your system.

Pressure Relief Procedure

Trapped air can cause the pump to cycle unexpect-
edly, which could result in serious injury from skin
injection or moving parts.
Do not lift or move motor while pressurized.
1. Engage the trigger lock.
2. Close the bleed-type master valve.
3. Disengage the trigger lock.
4. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger the gun to relieve pressure.
5. Engage the trigger lock.
6. Open all fluid drain valves in the system, having a
waste container ready to catch drainage. Leave
drain valve(s) open until you are ready to spray
again.
7. If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved after follow-
ing the steps above, VERY SLOWLY loosen tip
guard retaining nut or hose end coupling to relieve
pressure gradually, then loosen completely. Clear
hose or tip obstruction.
312796B

Repair Air Valve

Replace Complete Air Valve
1. Stop the pump at the middle of its stroke. Relieve
the pressure. See procedure at left.
2. Disconnect the air line to the motor.
3. For motors with DataTrak: Open cover of reed
switch assembly (31). Remove screw (32) to discon-
nect the assembly from the air valve (17).
31
32
Use a
T25 Torx
F
. 3: Reed switch assembly & air line removal
IG
4. Use a 10 mm socket wrench to remove four screws
(18). Remove the air valve (17) and gasket (16*◆).
Repair
air
line
ti12727a
9