Toshiba RAS-10SAV-A Service Manual page 20

Split wall type
Table of Contents

Advertisement

6-2. Outdoor Unit (RAS-10SAV-E, RAS-10SAV-A)
No.
Parts name
1
SC coil
(Noise filter)
2
DC-DC transformer
3
Reactor
4
Outside fan motor
5
Fan control relay
Outside air temp.
6
sensor (TO sensor)
Heat exchanger temp.
7
sensor (TE sensor)
Dischenge temp.
8
sensor (TD sensor)
9
Terminal block (6P)
Fuse
10
11
Electrolytic capacitor
12
IGBT
13
Compressor
14
Compressor thermo.
15
Rectifier
16
4-way valve coil
17
Running capacitor
(for fan motor)
Model name
L01
GET-0451
L03
GET-0452
SWT-72
CH-51-Z-T
SKF-240-20B-1
G5NB-1A
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-6B
For protection of switching power source
For protection of inverter input overcurrent
LLQ2G501KHUBTF
GT15J321
DA89X1C-23FZ
PW-2AL
D15XB60-4001
DS451155NPQB
– 19 –
FILE NO. SVM-07008
Rating
0.6mH, 15A
2.0 mH, 10A
Primary side DC280V, Secondary
side 7.0 V x 1, 12 V x 1, 17V x 2
L=19mH, 10A
20W
Coil DC12V Contact AC250V-1.5A
(25°C)
10k
10k
(25°C)
(20°C)
62k
20A, AC250V
3.15A, AC250V
25A, AC250V
500 F, DC 400 V x 3 pieces
15A, 600
3-phases 4-poles 750W
OFF: 125 ± 4°C, ON: 90 ± 5°C
15A, 600V
AC220-240V
AC 450V~, 1.5 F