Bosch Rexroth AG
Mounting
9
Interfaces
9.1
General Information
NOTICE
Connect the functional earth ground.
To avoid malfunctions, use only shielded cables and metallic or conductive
connector/coupling covers with large-area shield support.
9.2
Overview
The following connecting cable is available at the drawer keyboard:
Connection type
USB
Fig.9-1: Interface at the drawer keyboard
10
Mounting
10.1
Installation Notes
● Lay all connecting cables in loops and use strain reliefs for all cables.
● Keep as much distance as possible to noise sources.
10.2
Mounting
For mounting the drawer keyboard proceed as follows:
10/21
Rexroth IndraControl VAK 10.1, VAK 40.1 Drawer Keyboard
Material damages to electronics due to missing
functional earth ground connection!
Connector type (at the ca‐
ble)
USB A
DOK-SUPPL*-VAK*X0.1***-IT01-EN-P
Connection, external
USB-A female connector