Section I: Filter Installation; General Information - Pentair CLEAN AND CLEAR PLUS CCP240 Installation And User Manual

Cartridge
Table of Contents

Advertisement

SECTION I.
FILTER INSTALLATION
A. GENERAL INFORMATION
1. The Clean and Clear
mounted on a level concrete slab. Position the filter so
that instructions, warnings and the pressure gauge are
visible to the operator. It also should be positioned so that
the piping connections, control valve and drain port are
convenient and accessible for servicing and winterizing.
2.
Be certain to install electrical controls (e.g., on/off
switches, timers, control systems, etc.) at least five (5)
feet from the filter. This permits one to stand
clear of the filter during system start up.
3.
Allow sufficient clearance around the filter
to permit visual verification that the clamp is
properly installed around the tank flanges, see
Figure 1.
a.
Tap the clamp with a mallet or similar tool
to ensure uniform loading during clamp
tightening.
4.
Allow sufficient space above the filter to remove the filter lid for cleaning and servicing. This
distance will vary with the model of filter you are using. See Table 1 for the required vertical
clearance.
5.
Position the filter to safely direct water drainage. Rotate the High Flow™ Manual Air Relief Valve
to safely direct purged air or water. Water discharged from an improperly positioned filter or valve
can create an electrical hazard as well as damage property.
Risk of electrical shock or electrocution. Position the filter and manual air relief valve to safely
direct water drainage and purged air or water. Water discharged from an improperly positioned
filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property.
6.
Make all plumbing connections in accordance with local plumbing and building codes. Filter plumbing
connections are provided with an O-ring seal. If needed, use only a silicone base lubricant on the
O-rings. Do not use pipe joint compound, glue or solvent on the bulkhead connections.
Note: To seal the valve connections, use thread seal tape, thread sealant or plumbing paste
(non-petroleum base).
7. Remove the plug from the top of the filter lid and install the pressure gauge before use.
8. The maximum working pressure of this filter is 50 p.s.i. Never subject this filter to pressure in
excess of this amount, even when conducting hydrostatic pressure tests.
When performing hydrostatic pressure tests or when testing for external leaks of the completed
filtration and plumbing system, insure that the MAXIMUM PRESSURE that the filtration system
will be subjected to DOES NOT EXCEED THE MAXIMUM WORKING PRESSURE OF
ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most cases, the
maximum pressure will be stated on each component of the system.
Plus Cartridge Filter should be
®
CLEAN AND CLEAR
Table 1
Model No.
P/N
CCP240
160310
CCP320
160340
CCP420
160301
CCP520
160332
PLUS Cartridge Filter Installation and User's Guide
®
Figure 1
Size
Vert. Clearance
Req.
240 sq. ft.
56 in.
320 sq. ft.
62 in.
420 sq. ft.
68 in.
520 sq. ft.
74 in.
1

Advertisement

Table of Contents
loading

Table of Contents