Siemens TC3 Series User Manual page 15

Cellular engines
Table of Contents

Advertisement

TC3x Multiplexer User's Guide
Example for the second logical channel:
[CHANNEL2]
; type specifies the executable to start
Type=PORT
; own server name
Name=channel1
; default destination [CONTROL]
Destination=ctrl
; serial interface
Port=COM25
Baud=57600
DataBits=8
; parity: 0=no, 1=odd, 2=even, 3=mark, 4=space
Parity=0
; stop bits: 0=1, 1=1.5, 2=2
StopBits=0
Example for the third logical channel:
[CHANNEL3]
; type specifies the executable to start
Type=PORT
; own server name
Name=channel1
; default destination [CONTROL]
Destination=ctrl
; serial interface
Port=COM26
Baud=57600
DataBits=8
; parity: 0=no, 1=odd, 2=even, 3=mark, 4=space
Parity=0
; stop bits: 0=1, 1=1.5, 2=2
StopBits=0
Note:
The examples given assume that virtual COM Ports have been installed. Instead of COM24 you
may connect any other virtual channel or physical channel (when using 7 COM ports). The
sections for CHANNEL2 and CHANNEL3 need to be filled out accordingly.
Now all hardware and software components have been installed and you can work with the PC Mux.
TC3x_UG_01_V03.10 - Released
Page 15/50
10.01.2002

Advertisement

Table of Contents
loading

Table of Contents