Siemens TC3 Series User Manual page 14

Cellular engines
Table of Contents

Advertisement

TC3x Multiplexer User's Guide
• Section CHANNEL0
This section contains the configuration of the physical COM port your DSB35 or TC35T is
connected to. You may modify the selected Port and the Baud rate. When using all 3 virtual
channels, we recommend you use a baud rate of 57600 bps (AT+IPR=57600<CR><LF>).
Note :
Autobauding must be turned off!
Example for the physical channel:
[CHANNEL0]
; type specifies the executable to start
Type=PORT
; own server name
Name=hardware
; default destination [CONTROL]
Destination=ctrl
; serial interface
Port=COM1
Baud=57600
DataBits=8
; parity: 0=no, 1=odd, 2=even, 3=mark, 4=space
Parity=0
; stop bits: 0=1, 1=1.5, 2=2
StopBits=0
• Sections CHANNEL1 to CHANNEL3
These sections contain the configuration of the 3 virtual (or physical) COM ports. As above you
may modify the Port and Baud settings. A baud rate of 19200 bps is sufficient, but 57600 are
recommended. The baud rate setting has no impact on the virtual COM Ports, but is only
relevant when using physical ports.
Example for the first logical channel:
[CHANNEL1]
; type specifies the executable to start
Type=PORT
; own server name
Name=channel1
; default destination [CONTROL]
Destination=ctrl
; serial interface
Port=COM24
Baud=57600
DataBits=8
; parity: 0=no, 1=odd, 2=even, 3=mark, 4=space
Parity=0
; stop bits: 0=1, 1=1.5, 2=2
StopBits=0