7 Installation

Risk of short-circuit!
In the case of electronics with housing, water may condense within the housing!
▶ Let the electronics acclimate itself for several hours, as otherwise water may
condense in the housing.
▶ When installing the product, use the seals provided for that purpose.
▶ When working on electronics, observe strictest cleanliness and make sure that
no fluids will enter the housing.
Major potential differences!
Risk of destruction of electronics by plugging or unplugging connectors under
voltage.
▶ Switch off power supply to the relevant system part before installing the
products or plugging or unplugging connectors.
External electromagnetic interference!
Risk of malfunction.
▶ The distance to radio sources must be sufficiently large (>> 1 m).
▶ Do not lay solenoid or signal cables near power cables.
▶ Shield command and actual value cables. Connect the shield to system
ground on both ends.
7.1

REQUIRED TOOLS

To connect flexible cables to the terminals of the VT-SSV-1-2X you require a
screwdriver (flat head 3.0 x 0.5 mm, and for the flat head screw 5.5 x 1.0 mm).
Further tools are not required.
7.2

INSTALLATION CONDITIONS

▶ When installing the amplifier, strictly adhere to the ambient conditions
specified in data sheet RE 30262.
▶ The housing of the VT-SSV-1-2X features protection class IP65. Requirements
that exceed type of protection IP65 have to be ruled out. Avoid contact of the
VT-SSV-1-2X with hydraulic fluids, acids, bases, corrosive agents, salts, metal
vapors, solvents, etc.
7.2.1

Place of installation

Electronics from Bosch Rexroth are intended for mounting on on/off valves in
hydraulic systems and machines.