Items
(O)
Timing
Confirmation
(P)
RSSI Level
*
Confirmation
(Q)
Power RAMP
Confirmation
Adjustment
Point
-
Follow steps 1 to 3 of (J) above.
4.Confirm that the Timing accuracy is < ± 0.5ppm.
-
Follow steps 1 to 3 of (J) above.
4.Set DECT tester power to -81dBm.
5.Execute the command "readrssi".
6.Confirm that the returned value is 0×11 ± 8 (hex).
7.Set DECT tester power to -63dBm.
8.Execute the command "readrssi".
9.Confirm that the returned value is 0×1E ± 8 (hex).
-
Follow steps 1 to 3 of (J) above.
4.Confirm that Power RAMP is matching.
Procedure*
69
Check
Replace
Parts
IC1, IC3,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76
IC1, IC3,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76
IC1, IC3,
C54, C60,
C61,
C62, C63,
C64,
C65, C66,
C67,
C69, C81,
C82,
C56, R58,
R55, R76