Wiring Swing Guard T; Wiring Bodyguard-T; Wiring Superscan-T; Wiring Holding Beam - Stanley 204143 Installation And Operation Manual

For swing and fold doors
Table of Contents

Advertisement

iQ Control Box

Wiring Swing Guard T

Caution:
Do not connect Swing Guard T Daughter Board or Sensors until control box is fully tuned.
NOTE:
Select Swing Guard T when in
has not been connected at this time. If tuning with 'Hand Held Device', select Swing Guard T for Safety Logic.
1. Set DIP switches on the Swing Guard T Controller so that the sensor is always enabled (DIP switch 3
DOWN for auto).
2. To perform a
first learn
the door will not open and the
Override to ON.
3. Wire SU100 into TB4.
NOTE
: Do not use purple wires on Swing Guard T Controller wire harness.
TB1 Terminal
1
2
3
4
NOTE
: Refer to the Swing Guard T installation manual for Sensor Head mounting locations, DIP switch
settings, angle adjustments and routing of wire harnesses.

Wiring Bodyguard-T

The Bodyguard-T does not require a lockout relay for use with the iQ control box. The iQ control box generates the
data signals for door open, closing, and closed positions. Refer to Attachment 2, 3 , or 4, as applicable for wiring
connections. Program the Bodyguard-T Relay Output to #1.

Wiring Superscan-T

Refer to Attachment 2, 3 , or 4 as applicable for wiring connections.

Wiring Holding Beam

The Holding Beam input is used in applications when there is a rail-mounted holding beam. When the door is
closing and the beam is obstructed, the door will not open until the door is completely closed and the header-
mounted sensor becomes active. When the door is open and the beam is obstructed, the door will remain open.
Refer to Attachment 2, 3 , or 4 as applicable for wiring connections.

Wiring Other Sensors

Refer to Attachment 2, 3, 4 or 5 as applicable for wiring connections.
Step 9 of Table 1
on the Swing Guard T system, Manual Mode Sensor Override must be set to OFF or
will not complete. Once the
learn
Connection
(+) Power for Swing Guard T
Serial Communication
Serial Communication
(-) Power for Swing Guard T
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5
if tuning with pushbuttons, even though Swing Guard T
is complete, set Manual Mode Sensor
learn
Swing Guard T Wire Color
Red
Green
White
Black
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents