6.4 Speed control knob option (P3)

The speed is set using a knob with graduations from 15 to 100
percent. Has two indicator lamps. It is connected on the P2 con-
nector.

6.5 Internal speed control option (P4)

The speeds are set on potentiometers, which are accessible once
the cover has been removed.
- a max. spd potentiometer: calibration of the maximum speed
- a min. spd potentiometer: calibration of the minimum speed
- an int. spd potentiometer: speed control, which replaces control
via
the control knob.
There are also two indicator lights.

6.6 Braking resistor option (RF100 - RF200)

For operation in four quadrants and energy dissipation, resistors are
mounted directly onto the IntelliGear Plus.
IntelliGear Plus
Input
Frame
Voltage
230 VAC
31 / 32
460 VAC
External resistors with greater continuous power rating can be used, provided that the minimum ohmic value is maintained.
Browning, IntelliGear, Intelligear Plus are trademarks of Regal Beloit Corporation or one of its affiliated companies.
UL is believed to be a registered trade name and/or trademark of Underwriters Laboratories, Inc. and is NOT owned or controlled by Regal Beloit America Inc.
©2015 Regal Beloit Corporation, All Rights Reserved. MCIM15100E • Form 9112E • Printed in USA
RF100
Minimum
Resistance
Power (Watts)
(ohms)
Peak
700
180 ohms
2800

6.7 Fieldbus options

The interface card is fixed inside the casing cover. Protocol: Profi-
bus DP.

6.8 Parameter-setting console option (Keypad LCD)

The console option provides access to the drive internal settings
(terminal block configuration, ramp, speed and PI settings, etc.).
See IntelliGear Plus parameter-setting manual included.
Description of the option:
1 Keypad LCD console
1 cable (3m long)

6.9 Programming CD (VMA30SOFT)

This CD with manual provides access to the drive internal settings
(terminal block configuration, range, speed and PI settings, etc.).
Descriptions of the option:
1 CD in case
1 cable (3m long with USB on PC to RJ45 on IntelliGear Plus)

6.10 XPress Key (PX Key)

The XPress Key option is used to save a copy of all the IntelliGear
Plus parameters so that they can be duplicated very simply in
another drive.
Power (kW)
Cont
Peak
100
700
100
2800
RF200
Resistor
Connection
Cont
200
Series
200
Series