Download Print this page

A.O. Smith DRE 52 Installation, User And Service Manual page 52

Electric commercial water heater

Advertisement

Available languages

Available languages

Indication
A safety device is
activated
EN
50
Cause
The main safety thermostat (G1) is
activated
The row safety thermostat (G2) is
activated.
The thermal fuse broke the control
circuit.
Measure
-
Make sure the water heater is
completely filled.
-
Tap off water, so the temperature
drops in the water heater.
-
Make sure all connections are
connected correctly (refer to the wiring
diagram (see A.5)).
-
Use the white button to manually reset
the thermostat.
-
If necessary, replace the safety
thermostat (G1).
-
Tap off water, so the temperature
drops in the water heater.
-
Make sure all connections are
connected properly (refer to the wiring
diagram (see A.5)).
-
Use the red button to manually reset
the thermostat.
-
If necessary, replace the safety
thermostat (G2).
-
Check what caused the excessive heat
rise of the element area.
-
Measure the resistance value over the
thermal fuse. The value needs to be
<5 Ohm.
-
If necessary, replace the thermal fuse
wiring.
Installation, Maintenance and Service part

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Dre 80