OPERATING INSTRUCTIONS & INSTALLATION
No
ITEM
16
F-DEF-SENSOR
17
F-FAN ERROR
18
C-FAN ERROR
19
CF-SENSOR
F-DEFROSTING
20
ERROR
21
CF-FAN ERROR
22
CR-FAN ERROR
23
-
ICE PIPE
24
HEATER ERROR
Uart
25
COMMUNICATI
ON ERROR
L
M COMMUNICATI
26
ON ERROR
P
M COMMUNICATI
27
ON ERROR
TROUBLE
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case
of displaying a temperature defect, it is only displayed when sensor detection
temperature is not lower than 122
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant
fan motor.
Error is displayed in case there is contact failure on the feedback signal line,
motor wire missing or defect of the motor itself when operating the relevant
fan motor.
Electric wire cut, short-circuit, contact failure, sensor housing missing, while in
case of displaying a temperature defect, it is only displayed when sensor
detection temperature is not lower than 122 nor higher than -58
Error occurs and is displayed when regarding the F compartment defrosting heater, there is a electric wire
cut, short-circuit, contact failure, of sensor housing missing, or defective temperature fuse. A defect is
displayed if defrosting is not finished after continuous heating for more than 80 min, for the F compartment.
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant fan
motor.
Error is displayed in case there is a contact failure on the feedback signal line,
motor wire missing or defect of the motor itself, when operating the relevant fan
motor.
Error is displayed in case of ice pipe heater housing missing or
electric wire cut.
Communication error with the electric power cord MODEM
Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound
if communication between MICOM MAIN LOAD is not achieved due to an
interruption of more than 10 seconds.
Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound
if communication between MICOM MAIN PANEL is not achieved due to an
interruption of more than 10 seconds.
30
30
nor higher than -58
REMARK