Error Messages And Troubleshooting; Repair; Error Messages; Checking The Mechanical And Electrical Configuration - Siemens SIWAREX WL260 Series Operating Instructions Manual

Weighing systems. load cells.
Hide thumbs Also See for SIWAREX WL260 Series:
Table of Contents

Advertisement

Error messages and troubleshooting

8.1

Repair

Note
Unnecessary costs for repairs
Please only return faulty load cells to our repair center accompanied by an accurate description
of the fault. This simplifies the diagnostics.
8.2

Error messages

Rated load exceeded
If load cells are loaded beyond their rated load, this can result in an error message in the
weighing module.
When step changes in load cannot be excluded during measuring, for example, due to
application of a load in free fall, appropriate precautions to avoid damage to the load cell must
be made, e.g. by using elastomer bearings or load cells dimensioned for higher rated loads.
Wire break
The weighing module reports a wire break if the jumpers are not installed in load cells with four-
wire technology. For details, see section Connecting up (Page 29).
8.3

Checking the mechanical and electrical configuration

In the case of faulty measurements, check the following:
• Do any force bypasses exist, e.g. due to cables, pipes or guides, that generate forces in the
measuring direction?
• Are there any other disturbances due to soiling or thermal expansion?
• Have all load cells been correctly aligned horizontally and at the same height?
• Has moisture penetrated the junction box?
• Are the cables connected correctly?
• Are the cables damaged?
SIWAREX WL200
Operating Instructions, 12/2021, A5E02199611B-13
8
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siwarex wl250 seriesSiwarex wl230 seriesSiwarex wl270 seriesSiwarex wl280 seriesSiwarex wl290 seriesSiwarex wl260 sp-s aa ... Show all

Table of Contents